Pelco C603M-A (11/07) Pet Fence User Manual


 
C603M-A (11/07) 19
CONNECTING A PTZ DEVICE, RELAY, AND ALARMS
The NET5301T-I incorporates a 16-pin terminal block to support the following:
PTZ device, such as a dome camera, using the Pelco P or Pelco D protocol (RS-422)
Relay control, either normally open or normally closed
Up to three alarm inputs, supervised or unsupervised, using any combination of high and low signals
The terminal block has tension clamps instead of screw terminals. Use a small screwdriver to open the clamp for a particular lead. Figure 14
shows how to wire the terminal block and connect it to the NET5301T-I.
NOTE: The terminal block is keyed. It attaches only one way to the video encoder.
Figure 14. NET5301T-I Terminal Block
Table B identifies the pin assignments for the terminal block. An arrow on the rear panel identifies pin 1; on the terminal block, pin 1 is the
left-most lead on the top row (refer to Figure 14).
Table B. PTZ, Relay, and Alarm Pin Assignments
Top Row Bottom Row
Pin Label Lead Pin Label Lead
1 TX- RS-422 Data TX- 9 TX+ RS-422 Data TX+
2 RX- RS-422 Data RX- 10 RX+ RS-422 Data RX+
3 Ground 11 NC Relay Normally Closed
4 C Relay Common 12 NO Relay Normally Open
5 RX Reserved 13 TX Reserved
6A
1 Alarm 1 14 Ground
7A
2 Alarm 2 15 Ground
8A
3 Alarm 3 16 Ground
PIN 9
PIN 16
PIN 1
PIN 1