Panasonic M1111TY0 -FJ Plumbing Product User Manual


 
9
Basic
operations
1. Basic operations
1-1-5. Manual transition
Operate the fader lever to execute transitions manually.
If the fader lever has been operated during auto transition,
auto transition will be switched to manual operation as soon
as the fader position overtakes the amount of the transition
being executed.
The bus tally LEDs on the left of the fader lever indicate the
program bus output status.
Top LED only lights PGM/A bus output
Top and bottom
LEDs light
During the transition
Bottom LED only
lights
PST/B bus output
1-1-6. Auto transition
When the [AUTO] button is pressed, the transition is
executed automatically using the transition time which has
been set.
The transition is executed in the remaining time when the
[AUTO] button is pressed while the fader lever is being
operated.
The auto transition time is set using the Time menu.
Press the t button to light its indicator, and display the
Time menu.
Use [F1] to display the BKGD sub menu.
Set the transition time.
When setting the transition time in frame units
Use [F4] to set the transition time in frames.
When setting the transition time in second units
Use [F3] to set the time in seconds and [F4] to set it
in frames.
The display unit is set by selecting Config menu
Operate sub menu Time Unit item.
Sec The time is displayed as a number of
seconds.
Frame The time is displayed as a number of frames.
Any time from 0 to 999f can be set. The time which can
be set when seconds are used as the display unit differs
depending on the system format.
59.94i: max. 33s09f 59.94p: max. 16s39f
50i: max. 39s24f 50p: max. 19s49f
24PsF: max. 41s15f 23.98PsF: max. 41s15f
1-1-7. Cut transition
When the [CUT] button is pressed, the transition is executed
instantly.