Panasonic CU-HE9DKE Air Conditioner User Manual


 
Fig. 17
13.3.2.6. Removal of Vacuum Pump
1. Remove the Cabinet Top Plate and Cabinet Front Plate
according to 13.3.2.1.
2. Remove the Control Cover and Terminal Cover according
to 13.3.2.2.
3. Remove the screws (two) fixing Terminal part and the
Cabinet Side Plate.
Fig. 18
4. Remove the Cabinet Side Plate by removing the screws
(five).
A screw of among the five is under the back side of the
Outdoor unit.
Fig. 19
5. Disconnect the cable of the Vacuum Pump from the
Connector (white).
6. Disconnect the hose from the Vacuum Pump by loosening
the clip with tools such as pliers.
Note: Do not remove the connecting materials (Black
rubber) on the intake side from the hose.
Fig. 20
Connect two hoses correctly when reassembling the
Vacuum Pump. Incorrect connection may cause failure.
7. Remove the screws (three) for the Vacuum Pump.
Fig. 21
8. Remove the Vacuum Pump by holding up the backside of
the Vacuum Pump Holder a little and pulling it in with
inclined to the left side.
Fig. 22
80
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE