Airflow direction, Fan speed and Setting temperature are
optimized.
•
• •
•
“[Intake Air temperature] - [Remote controller setting
temperature]” is detected every 30 seconds by indication
from indoor unit and controlled to each area.
Quick Cooling
→
Unit forcibly turns to Quick Cooling operation
for 5 minutes after Powerful-ON even through it is in the Chilly
Cooling area.Chilly Cooling
→
Discharge air temperature is
kept low by changing fan speed according to room temperature
and chilly feeling will be produced.
•
• •
•
Airflow direction, Fan speed and Setting temperature are
optimized.
•
• •
•
“[Intake air temperature] - [Remote controller setting
temperature]” is detected every 30 seconds by indication
from indoor unit and controlled to each area.
Quick Cooling
→
Unit forcibly turns to Quick Cooling operation
for 5 minutes after powerful-ON even through it is in the Chilly
Air Cooling area.Chilly Cooling
→
Discharge air temperature is
kept low by changing fan speed according to room temperature
and chilly feeling will be produced.
air having a constant temperature.
•
• •
•
Refer to the “Indoor Fan Control” chapter for fan speed of each model.
3. Thermostat-OFF
In thermostat-OFF, fan will operate repeatedly between the speeds of “SLo” for 20 second and “SSLo” for 100 seconds. (Refer
to the “Indoor Fan Control” chapter.)
4. Forced Heating Operation
In Forced Heating mode operation, fan speed is “Hi”. (Refer to the “Indoor Fan Control” chapter.)
9.7. Powerful Operation
If the POWERFUL button is pressed during operating in Cooling, Heating, Dry or AUTO, the unit always forces to operate in
respective modes (Quick Cooling, Quick Heating and Dry) for 5 minutes, which fan speed is "SHi" even though unit is in each
stable area.
9.7.1. Cooling Operation
9.7.2. Dry Operation
30