9.12. Ionizer Operation
Single Ionizer Operation
•
• •
•
The unit turns to single Ionizer operation mode by pressing the ION button on the remote controller at stop mode and the
ION LED (Green) on the main unit will light up.
* Temperature setting is not possible during the operation.
Simultaneous Ionizer Operation (Heating, Cooling, Dry and Auto)
•
• •
•
The unit turns simultaneous Ionizer operation mode by pressing the ION button on the remote controller at each
operation mode (Heating, Cooling, Dry and Auto) and the ION LED (Green) on the main unit will light up. The LED will
be off by pressing the button again, but the unit remains the operation.
* To stop all the operations, press the OFF/ON button on the remote controller.
Single blinking of the ION LED does not indicate Breakdown.
When unit was operated under the condition that a discharge insulation of the Ion generator is deteriorated (Dust, Attached
water, etc.):
If the insulation deterioration of the unit discharge part is big;
Insulation deterioration will be detected in and after 2 seconds from the unit operation starting, and the unit will turn off for 30
minutes and turn on again. When this operation is repeated 24 times, the ION LED will start blinking. But, if the unit operation
is stopped or the Ionizer is operated properly for 10 minutes, the count will be cleared.
Condition resolutive
It can be canceled by stopping the operation during the ION LED blinking.
33
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE