Panasonic CU-HE9DKE Air Conditioner User Manual


 
Heating Operation Mode
Manual Operation Vertical Automatic Operation Powerful-ON
Five-level setting is possible with the remote
controller.
1. When heat exchanger temperature is less
than 32°C.
2. When heat exchanger temperature is
between 32°C and 56°C.
3. When heat exchanger temperature is 56°C
or more.
1. When heat exchanger temperature is less
than 32°C.
2. Quick Heating Operation
3. Warm Heating Operation
4. When heat exchanger temperature is 56°C
or more.
The vertical louver is closed when the unit is turned off with the remote controller. (Stop position)
The vertical louver is fully opened and move to the setting position when the unit is turned on with the remote controller.
The vertical louver remains at open position when the unit is turned off during operation.
The values in the parentheses ( ) are for the models: CS-HE12DKE.
24
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE