Panasonic CS-HE9DKE Air Conditioner User Manual


 
14.2. Sensible Capacity Chart
CS-HE9DKE CU-HE9DKE
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 2.58 2.33 0.46 2.41 2.24 0.50 2.24 2.14 0.54 2.04 2.03 0.59
19.0°C 2.60 0.51
19.5°C 2.83 2.44 0.47 2.65 2.34 0.51 2.46 2.25 0.55 2.24 2.14 0.60
22.0°C 3.09 2.52 0.49 2.88 2.43 0.53 2.68 2.34 0.57 2.44 2.24 0.62
CS-HE12DKE CU-HE12DKE
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 3.42 2.86 0.77 3.20 2.75 0.84 2.97 2.64 0.90 2.70 2.51 0.97
19.0°C 3.45 0.85
19.5°C 3.76 3.01 0.79 3.51 2.89 0.85 3.27 2.78 0.92 2.97 2.64 0.99
22.0°C 4.10 3.12 0.80 3.83 3.00 0.87 3.56 2.89 0.94 3.24 2.75 1.01
83