Panasonic CS-HE9DKE Air Conditioner User Manual


 
9.13.1. Oxygen Enrich System Figure
9.13. Oxygen Enrich Operation
9.13.2. Indoor Fan Control
Single Oxygen Enrich operation
1. Manual fan speed ............. Not available for the remote controller.
2. Automatic fan speed ............. Fixed.
Revolution (rpm)
Normal Fan Speed (AUTO) 480
When used in common with other modes, it will be followed by other modes.
Order of priority: Cooling, Dry and Heating > Ion > Oxygen Enrich
Powerful and Quiet operations are not accepted at the Oxygen Enrich Operation mode.
9.13.3. Indoor Airflow Direction Control
1. Manual and Automatic Airflow Direction ................. Same as Cooling operation.
When used in common with other modes, it will be followed by other modes.
Order of priority: Cooling, Dry and Heating > Ion > Oxygen Enrich
9.13.4. Conditions of starting and cancellation
1. ON/OFF by the "Oxygen & Ventilation Selection" Switch on the remote controller
When "Oxygen" is selected with the Switch under a condition of Ionizing Air Clearing OFF
Single Oxygen Enrich Operation
When "Oxygen" is selected with the Switch under a condition of Ionizing Air Clearing ON,
Ionizing Air Cleaning + Simultaneous Oxygen Enrich Operation
When "Oxygen" is selected with the Switch during Single Oxygen Enrich Operation,
Operation is stopped.
When "Oxygen" is selected with the Switch during Cooling, Heating, Dry or Ionizing Air Cleaning Operation,
Cooling, Heating, Dry or Ionizing Air Cleaning Operation + Simultaneous Oxygen Enrich Operation,
When "Oxygen" is selected with the Switch during Cooling, Heating, Dry or Ionizing Air Cleaning Operation + Simultaneous
Oxygen Enrich Operation,
34
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE