13.3.1.5. Removal of Oxygen Discharge
Outlet
1. Remove the Front Grille according to the procedure
13.3.1.1.
2. Remove the Oxygen Discharge Outlet from the Heat
Exchanger and remove the Oxygen Tube by releasing the
hooks (four) on the plastic part.
Note: The Oxygen Discharge Outlet is on the left side.
Fig. 22
Fig. 23
13.3.1.6. Removal of Air Swing Motors for
Vertical and Horizontal Louvers
1. Remove the Front Grille according to the procedure
13.3.1.1.
2. Remove the Discharge Grille.
Note: Pulling up the Discharge Grille a little can make
the Drain Hose easy to be removed.
•
• •
•
The Air Swing Motor for Vertical Louver can be removed
without removal of the Discharge Grille.
Fig. 24
3. Remove the Motors by removing the screws (one each) for
the Motors and the cable connector.
Fig. 25
13.3.1.7. Removal of Ventilation Motor
1. Remove the Front Grille according to the procedure
13.3.1.1.
2. Remove the Connector (white) for the Ventilation Motor and
the screws (two).
Fig. 26
Fig. 27
3. Pulling out the Ventilation Motor by releasing the hook
(one).
Note: The Fan Joint Duct Part under the Ventilation
Motor can not be removed. Remove the Indoor unit
from the Chassis Complete for servicing.
Fig. 28
75