Applicable piping kit
CZ-3F5, 7BP (HE9DKE)
CZ-4F5, 7, 10BP (HE12DKE)
SELECT THE BEST LOCATION
INDOOR UNIT
•
• •
•
There should not be any heat source or steam near the
unit.
•
• •
•
There should not be any obstacles blocking the air
circulation.
•
• •
•
A place where air circulation in the room is good.
•
• •
•
A place where drainage can be easily done.
•
• •
•
A place where noise prevention is taken into
consideration.
•
• •
•
Do not install the unit near the door way.
•
• •
•
Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
•
• •
•
Recommended installation height for indoor unit shall be
at least 2.5 m.
OUTDOOR UNIT
•
• •
•
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
•
• •
•
There should not be any animal or plant which could be
affected by hot air discharged.
•
• •
•
Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
•
• •
•
Do not place any obstacles which may cause a short
circuit of the discharged air.
•
• •
•
If piping length is over the common length, additional
refrigerant should be added as shown in the table.
Indoor/Outdoor Unit Installation Diagram
•
• •
•
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Attached accessories
47
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE