Orbit Manufacturing ORBIT-6 RP-206 Smoke Alarm User Manual


 
Installer Manual
21
17
Special Emergency Keying Follow (Latched)
UO is activated immediately when pressing the keypad’s [7] and [8] keys simultaneously
for two seconds. U0 is deactivated when the system is disarmed.
18
Special Emergency Keying Follow (Pulsed)
UO is activated for several seconds when pressing the keypad’s [7] and [8] keys
simultaneously for two seconds.
19
Fire Keying Follow (Latched)
UO is activated immediately when a Fire alarm is triggered by a violation of zone 5,
defined as Fire, or by pressing the keypad’s [4] and [5] keys simultaneously for two
seconds. U0 is deactivated when the system is disarmed.
1A
Fire Keying Follow (Pulse)
UO is activated when a Fire alarm is triggered by a violation of zone 5, defined as Fire,
or by pressing the keypad’s [4] and [5] keys simultaneously for two seconds.
1B
User Activated (Toggle)
UO may be activated by the user through the entry of [*]+[2]+[User Code]+[X], where X
refers to the utility output number.
The first entry of the above sequence activates the UO and causes it to latch in the
opposite of its current state. The system briefly lights the Zone LED corresponding to the
selected UO and produces a single confirming beep subsequent entries toggle the
response from ON to OFF to ON, etc.
1C
User Activated (Pulse)
UO may be activated by the user through the entry of [*]+[2]+[User Code]+[X], where X
refers to the utility output number.
The entry activates the UO for several seconds (pulse). The system briefly lights the
Zone LED corresponding to the selected UO and produces a single confirming beep
subsequent entries repeat this pattern.
1D
AUX POWER Switch (Fire)
Until triggered, UO is normally activated and is designed to be a part of the circuit
supplying power to the Smoke Detector(s); see Figure 1A and 1B.
After a Fire Alarm is disarmed, it may be necessary to reset any Smoke Detector(s)
which may be “latched” in alarm. A “latched” Smoke Detector will cause the keyboard’s
FIRE LED to remain lit, even though the panel may be disarmed. To reset a Smoke
Detector, a “UO” used in this manner must be momentarily deactivated; this action is
performed by the user, who must enter [*]+[2]+[User Code]+[X], where [X] refers to the
UO number (i.e. 1,2,3, or 4) in the circuit providing Smoke Detector power. If this is not
done, it will be impossible to arm the panel; please advise your customer of this
contingency which is stated in the ORBIT-6’s User Manual.
1E
Duress Code Follow (Pulse)
U0 is activated for several seconds (and then deactivates) when any duress code is
entered.
1F
AC Loss Follow (Latched)
U0 is activated due to a lack of power from the commercial AC. U0 is deactivated when
the system is operating properly from commercial (AC) power.
20
AC Loss Follow (Pulse)
U0 is activated for several seconds (and then deactivates) due to a lack of power from
the commercial AC.
21
Low Battery Follow (Latched)
U0 is activated due to low power from the backup battery. U01 is deactivated when the
battery is in good condition.
22
Low Battery Follow (Pulse)
U0 is activated for several seconds due to low power from the backup battery.
23
Voice Module Enable
The U0 is activated after FM phone number dialing has been made due to alarm. The U0
deactivates after the FM period termination.