GENERAL SYSTEM PARAMETERS: LOCATIONS 00–05
Location: 00 Default Enable: Def: 00
PURPOSE: to enable or disable the option of resetting the system to the factory
defaults.
00 Enable the option of resetting the system to the factory defaults.
55 Disable the option of resetting the system to the factory defaults.
Location: 01 MS Lock: Def: 000000
§ MS Lock is a 6-digit security code used in conjunction with Rokonet’s
Upload/Download Software
§ It is designed to provide greater proprietary security to the Central Station
parameters
§ It is NOT necessary to change the MS Lock default value within Installer
Programming; instead, the procedure may be performed from the
Upload/Download Software and then downloaded to the ORBIT-6
for additional information, refer to the Upload/Download Programming
Manual
Location: 02 Phone Number: Primary Central Station (Central Station 1)
To delete an existing phone number, simply press the [#] key; to enter or replace the
phone number required to reach the primary Central Station include all access digits
(e.g. 0 to 9) and the area code. If required, include the following special functions to
achieve the effect listed in the table:
FUNCTION SEQUENCE
RESULTS
stop dialing and wait for a new dial tone [STAY], [1] A
wait a fixed period before continuing [STAY], [2] B
switch from Pulse to Tone (or from Tone to Pulse)
[STAY], [3] C
send the DTMF Q character
[STAY], [
*
]
*
send the DTMF # character [STAY], [#] #
When done with your complete entry, press [#] to store it. Up to 24 digits can be
entered to the phone number.
For your records, enter the complete phone number below:
Location: 03 Phone Number: Secondary Central Station (Central Station 2)
Same as in Location 02