Napoleon Fireplaces GD19N Indoor Fireplace User Manual


 
7
W415-0612 / C / 01.25.08
Use the GD201 periscope kit to locate the air termination
above grade. The periscope must be installed so that when
nal grading is completed, the bottom air slot is located a
minimum of 12" above grade. The maximum allowable vent
length is 10 ft.
16”
MINIMUM
35 FT MAXIMUM
3 FT MINIMUM
16”
MINIMUM
35 FT MAXIMUM
3 FT MINIMUM
FIGURE 4a
The maximum vent length for a corner installation is 20" of
horizontal run, in addition to the 45° offset. In this case zero
rise is acceptable when using rigid. See FIGURE 5a. Flexible
venting must maintain a 6" rise. See FIGURE 5b.
TYPICAL VENT INSTALLATIONS
PERISCOPE TERMINATION CORNER TERMINATION
FIGURE 5b
FIGURE 5a
FIGURE 4b
FIGURE 2a
FIGURE 3a
FIGURE 2b
FIGURE 3b
24" MAXIMUM
20" MAXIMUM
26
3
/8" MINIMUM
PLUS RISE*
10"
MINIMUM
43
1
/8" MINIMUM
PLUS RISE*
24”
MINIMUM
12”
MINIMUM
24”
MINIMUM
12”
MINIMUM
TOP EXIT INSTALLATION
REAR EXIT INSTALLATION
MAXIMUM 10FT VENT LENGTH
20” MAXIMUM
6” RISE
MINIMUM
* Refer to "Venting"
section.
TOP EXITREAR EXIT
SPECIAL VENT INSTALLATIONS
33
1
/8"