Napco Security Technologies GEM-X255 Home Security System User Manual


 
23
PROGRAMMING (OPTIONAL)
Reviewing a Programmed User Code
To review an existing User Code, enter the 2-digit user number and the corresponding User Code will display.
Exiting the User Program Mode
When you have completed programming or erasing User Codes, press C to exit the User Program Mode.
Programming Example
Program the User 30 Code to “3784”:
1
Enter your User Code, followed by A.
2
Answer NO (press F
) repeatedly until “ACTIVATE PROGRAM Y/N” is displayed, then press YES (E).
The display will read “ENTER USER CODE”
3
Press
030
for User No. 30, then press
A, A
,
followed by
3784
.
4
Press
J
to save the code.
5
Press
C
to exit the Program Mode.
Notes:
If the system contains more than one keypad, only the keypad designated “No. 1” may be used for programming (if in
doubt which is No. 1, ask your installer).
While in Program Mode, the ARMED and STATUS lights remain off and burglar and fire alarm functions are disabled.
In selecting your codes, do not program repetitive numbers (1111), consecutive numbers (1234), your birth date, address,
or other obvious combinations. Choose a code of up to six digits (a minimum of four is recommended, and required in UL
installations).If the keypad detects no Program Mode activity for more than 4 minutes, a tone will sound. Press
C to
silence.
GEM-X255_OI273_USER.pub
page 23
Tuesday, September 10, 2002 13:14