Napco Security Technologies GEM-P1664 Home Security System User Manual


 
X GEM-P1664 Installation Instructions
L NAPCO Security Systems
WI1424A 1/06
Page 30
the "Pre-Alarm Warning", then no report will be sent and no messages will be displayed at the keypad. If the area is disarmed during
the Abort-Delay, then an "Alarm Canceled' will be displayed at the keypad and no report will be sent. If the area is disarmed during or
within the Cancel Window Duration, then an "Attempting to Cancel" will be followed by an "Alarm Canceled" for a successful
cancellation. Otherwise, the report had been sent and will be responded appropriately to by the Central Station. Cancel must be
provided with a Central Station Telephone Number, proper Subscriber O/C Report ID Numbers and a valid Cancel Code to Telco 3.
A Cancel Window ("Report Cancel Window") is the duration that the system will attempt to cancel a report, after the report is sent.
Cancel Next Test Timer Report on Any Report See Test Timer
Central Station Receiver Data Format See Data Format
Chime (Displays "MONITOR" on GEM-RP2ASe2 Keypads); Chime Duration
This annunciator feature may be used on any zone to sound a tone at the keypad while disarmed when the zone goes into trouble.
Access the ACTIVATE CHIME function to enable or disable the Chime Mode. This feature is programmable by zone and "Chime
Timeout Duration". A time must be programmed for the chime to function. Note: "0" means no chime value is programmed.
Chime Zone 2
CHIME2 adds an additional tone onto the regular "Chime Zone" tone. It allows some zones to have distinctive annunciator chimes to
identify the door or zone. "Chime Zone" must be selected on any keypad for all area keypads to chime. While the standard chime
zone sounds a steady tone when a chime zone is faulted, Chime 2 will sound a pulsating tone when a Chime 2 zone is faulted. This
can be used to help the customer easily identify the door which has been opened. Program the zone as Chime 2 in the Zone
Features screen. This feature is programmable by zone and "Chime Timeout Duration".
Chirp Output on Keyfob Arm/Disarm
If enabled, when arming with a keyfob, the PGM2 output chirps.
Clear Program
Caution: Erases the dealer program. Use this feature to start a new customized default program. Access Address Location, then
press the
U or D button.
Closing Report; Closing Report Only on Conditional Closing; Conditional Closing; Include Selective/Group Bypass In
Conditional Closing/Status; Status Report; Disable Closing Report
On arming, the communicator can transmit a unique Closing Code for each user and a status report that identifies the problem zone
to the central station. Note that Subscriber Identification Numbers and a Closing Code and/or conditional closing code must be
entered for any closing report.
Select which users will report closings for each telephone number, even if "Closing Report Only on Conditional Closing" is selected.
Normally, a closing report will consist of the Closing Code and the number of the user that armed. If the user armed with an auto-
bypassed zone (or selective/group bypassed zone if "Include Selective/Group Bypass In Conditional Closing/Status" was
programmed), the Conditional Closing Code will also be sent.
Select "Closing Report Only on Conditional Closing" to report only when arming with an auto-bypassed zone (and selective-bypassed
zone if "Include Selective in Conditional Closing/Status" is programmed).
Select "Status Report" to send a closing followed by a status report that identifies the problem zone(s). A typical Status Report is
represented by the following example.
Example (4/2 Format). A burglar breaks into a commercial establishment during the night, breaking the window foil on Zone 5. The
Open/Close Subscriber Identification Number is "1234"; the Alarm Code for Zone 5 is "3,5" (Burglary Zone 5); the Subscriber
Identification Number is "6789"; the Closing Code is "C". The communicator will send the following report to the central station.
When alarm occurs:
"6789 35" – Alarm, Zone 5
Closing Report:
"1234 C1" – Closing, User 1 (User 1 returned, inspected damage & rearmed; the same transmission would occur for
User 11, 21, 31, etc.)
"1234 F5" – Trouble, Zone 5 (zone status at time of closing: Window foil still broken; Zone 5 auto-bypasses, repair
required; the same transmission would occur for Zone 15, 25, 35, etc.).
Cold Start
Caution: Erases the entire program (codes, schedules, etc.), and loads the following defaults: 8 hardwire zones (Zones 1-8) are pro-
grammed in Area 1, with no other zone features enabled and no alarms generated. In addition, a Default User 1 Code of "123" is en-
abled as an Arming Code in Area 1, and after powering up, the installer is required to enter Program Mode using the Dealer Program
Default Code of "456789". Press
C to exit the EZ Program menu. Access Location Cold Start, then press the U or D button.
Data Format
Glossary