Napco Security Technologies GEM-P1664 Home Security System User Manual


 
X GEM-P1664 Installation Instructions
L NAPCO Security Systems
WI1424A 1/06
Page 18
Compatibility Number (Not Applicable)
THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P1664 CON-
TROL PANEL. DO NOT CHANGE THIS SETTING.
Press the
A or R button to continue or press the C button to exit.
EZM Address
The keypad's internal EZM (Expansion Zone Module) may be utilized to
provide four additional wired zones. Whether used alone or in conjunction
with optional GEM-EZM series modules or other keypad EZMs, it must be
assigned a unique address (or Group number, see Keypad Programming
Workbook) similar to its keypad address. If no other EZMs are to be used,
designate the keypad as Group “01” at the “
EZM ADDRESS 00” display. In multiple-EZM systems, enter an assigned
group number “01” through “14”. (Each EZM must have a unique assigned group number, starting with “01” and
proceeding consecutively.) Press the
U or D button to save. Press the A or R button to continue or press the
C button to exit.
Zone Response
The normal loop response of each keypad expansion zone is 750mS,
however the response time of any zone can be reduced to 50mS as
follows.
1. Of the following, circle the number(s) in parentheses associated with
the zone(s) to be changed:
Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8)
2. Add up the circled numbers.
3. At the keypad, enter the sum as a two-digit number “01” through “15” on the display, then press the
U or D button.
Example. Change Zones 2, 3 and 4 to 50mS response.
1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8).
2. Add up the circled numbers: 2 + 4 + 8 = 14.
3. Enter “14” at the keypad, then press the
U or D button.
Press the
A or R button to continue or press the C button to exit.
Note: Panel Zone Response time can also be changed in Direct Address programming (first 8 zones only). See the
Programming Instructions WI1422 and WI1423 for more information.
Program Control Message (Not Applicable)
THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P1664
CONTROL PANEL.
Press the
R button to continue (the display will loop back through
selections, for changes) or press the
C button to exit the Keypad Configuration Mode (display will read “01 OUT OF
SYSTEM
”). Then replace Jumper JP1 across Pins 1–2 (top two).
New
Compat # 0000
EZM Address
00
Zone Response
00
Program Control
Message # 1
Keypad Configuration Mode