Multiquip ST-45HRM CE Heat Pump User Manual


 
MAYCO ST-45HRM CE PUMP — OPERATION & PARTS MANUAL — REV. #0 (02/23/04) — PAGE 71
General recommendations
If the site will permit, use steel pipe from the pump to the
pool perimeter. It will reduce line pressures which is highly
recommended.
The vibrator on the reducer by the pool improves pumpability.
Turn both air vibrators off whenever the pump is stopped to
prevent separation of mix.
The air vibrators are low consumption (4.2 scfm).
Leave the air on at the nozzle when the pump is stopped to
prevent clogging of air the hoses in the air insert.
Use item #11 (steel elbow) at the edge of the pool to prevent
collapse of the rubber hose, which can cause blockage.
RECOMMENDED SHOTCRETE SYSTEM
NO. PART NO. PART NAME QTY. REMARKS
1 EM28904 COUPLING, 3” H-D “CF”
2 EM23946 ELBOW, 3"x90°
3 EM28903 COUPLING, 2.5” H-D w/GASKET & PIN
4 EM28005DD REDUCER, 3”x2.5”x36” H-D ENDS
5 EM28061 PIPE, 2.5”x120w x 10’ H-D
6 EM24849 HOSE, 2.5”x2”x36” H-D
7 EM28001DD REDUCER, 2.5”x2”x36” H-D
8 EM23815D REDUCER, 2.5”x2” w/AIR VIBRATOR
9 EM28902 COUPLING, 2” H-D w/GASKET & PIN
10 EM23101 AIR VIBRATOR ASSY.
11 TBD 2”x2” ELBOW
12 EM24841 HOSE, 2”x25’ H-D w/ENDS
13 EM23808D NOZZLE ASSEMBLY, 2” H-D
14 EM23806 NOZZLE TIP, RUBBER 1-3/8”
15 EM23807 NOZZLE TIP, RUBBER 1.25”
APPENDIX — ST-45HRM CE SHOTCRETE SYSTEM