PUMP COMPONENTS (CONTINUED)
Figure 6 illustrates the location of the major components
for the LS600P Concrete Pump. The function of each
component is described below:
15. Documentation Box — Contains engine and pump
operation, parts and maintenance information.
16. Remixer Motor — Drives the remixer paddles inside
the hopper. The motor direction is controlled by the
remixer control lever.
17. — Lift hood to fill. Concrete from a
Redi-Mix truck is poured into this hopper. The hopper
can hold 10 cu. ft of concrete with optional forward/
reverse mixer. put hands or any other parts
of you body into the hopper.
18. Hydraulic Oil Sight Glass — Use to determine the
amount of hydraulic oil remaining in tank. The sight
glass also contains a temperature gauge for monitoring
the temperature of the hydraulic oil.
19. — Remove cap to add
hydraulic fluid. Fill with Shell Oil Tellus 68 or Mobil Oil
DFE26 if level is low.
20. Hydraulic Oil Filter — This in-tank return hydraulic
filter with a 10 micron cleanable filter is designed to
remove all particles large enough to cause wear and
job break down. Under normal conditions, replace
every 6 months.
21. Control Box — Contains the electrical components
required to run the pump. See control box components
section for component callouts.
22. Hydraulic Pump — This unit incorporates an axial
variable displacement hydraulic piston pump.
23. Engine — Perkins 1104D-44TA Turbo Diesel engine.
24. Radiator — Fill only with recommended coolant.
Radiator coolant capacity is 4.5 gallons (17 liters).
25. — This device is electronically
controlled by the cylinder stroke switch located on
the front panel of the control box. The function of the
volume control is to set the pumping stroke.
26. Lubrication Box — This box is empty when shipped
from the factory. Please fill with 3 gallons (11.35 liters)
of SAE 30 motor oil for first time use. Also check the
dual clean-out point on bottom of lubrication box for a
secure tight fit.
27. Heat Exchanger — The function of the heat exchanger
is to cool the hydraulic oil when pumping in high
temperature weather conditions. The exchanger draws
oil from the hydraulic tank through a filter and into
the heat exchanger before allowing it to flow into the
hydraulic system.
28. Accumulator — Stores hydraulic oil under pressure
and releases it to the shuttle cylinder and provides the
pressure needed to ensure enough force is provided
during cycle.
29. — This
feature is an option. Push the lever downward to
extend the left hydraulic stablizer. Push the control
lever upward to retract the stablizer.
30. — This
feature is an option. Push the lever downward to
extend the right hydraulic stablizer. Push the control
lever upward to retract the stablizer.
31. — Controls the forward/
reverse motion of the hopper remixer paddles.
32. Hopper Discharge Sleeve — Connect hoses or steel
pipes to the discharge sleeve for pouring concrete.
33. Rear Running Lights — ALWAYS check and make
sure both the right and left running lights are functioning
correctly before towing the pump