Monessen Hearth BLDV500N/PV7;N/PSC7 Indoor Fireplace User Manual


 
74D3000
5
BLDV7 Series Gas Fireplace

This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
This appliance is not for use with solid fuels.
The appliance is approved for bedroom or bedsitting
room installations.
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z3.1/NFPA 54 in the USA, CSA B149 in
Canada.
This appliance is mobile home appr-oved.
The appliance must be properly connected to a venting
system.
The appliance is not approved for closet or recessed
installations.

FP2073
BLDV controls
Off/Pilot/On Knob
Figure 1 -
BLDV7 Series Fireplace
(Millivolt Control shown)
Hi/Lo Knob
On/Off/RS
Switch
Ignitor
FP073

Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).

Natural Propane (LP)
Inlet Minimum 4.5” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Manifold Pressure 3.5” w.c. 10.0” w.c.

Max.Input Min. Input Orifice
Model Fuel BTU/h BTU/h Size
BLDV400NV7 Nat. 6,000 1,000 .5 mm
BLDV400PV7 LP 6,000 1,000 1/16 in.
BLDV400NSC7 Nat. 6,000 19,000 .5 mm
BLDV400PSC7 LP 6,000 1,000 1/16 in.
BLDV500NV7 Nat. 8,000 0,000 #38
BLDV500PV7 LP 7,000 ,000 1.55 mm
BLDV500NSC7 Nat. 8,000 0,000 #38
BLDV500PSC7 LP 7,000 ,000 1.55 mm