BLDV7 Series Gas Fireplace
The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5. Use two
() wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws
to attach fireplace to framing. The side nailing flanges are 1/" or 5/8" to accommodate different
wall thickness.


 Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to
final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating
of Zero) may be used to cover the black painted face of the appliance. It is permissible to bring
combustible wall board to the top and side edges of the black painted face. A 300°F minimum
adhesive may be used to attach facing materials to the black surface. If joints between the finished
wall and the fireplace surround are sealed, a 300°F minimum sealant material (General Electric
RTV103 or equivalent) must be used.
FP2335
nailing flanges
Figure 5 -
Securing Fireplace to Floor
and Framing Studs
Framing
Nailing Flange
Nailing Flange
Screws
Screw
Screw
Nailing
Flanges
Drywall Support
Tabs
(Do not use for
framing or header)
FP335