Monessen Hearth BLDV500N/PV7;N/PSC7 Indoor Fireplace User Manual


 
74D3000
0
BLDV7 Series Gas Fireplace

1
2
3
4
1
2
3
4
12” Min.
Figure 24 -
Maximum Elbow
Usage
FP1179


 For all top vent vertical through-the-roof installa-
tions, install the supplied cross-bar flue restrictor onto the
top edge of the firebox flue adapter. Figure 25
1. Locate your fireplace.
. Plumb to center of the
(4”) flue collar from ceiling
above and mark position.
3.
Cut opening equal to 9C\v” x
9C\v” (48 x 48 mm).
4. Proceed to plumb for addi-
tional openings through the
roof. In all cases, the
opening must provide
a
minimum of 1 inch
clearance to the vent
pipe, i.e., the hole must
be at least 9C\v” x 9C\v” (48 x 48 mm).
5. Place fireplace into position.
6. Place firestop(s) or Attic Insulation Shield into position
and secure. Figure 26
7. Install roof support (Figure 27) and roof flashing mak-
ing sure upper flange is below the shingles. Figure 29
8. Install appropriate pipe sections until the venting is
above the flashing. Figure 29
9. Install storm collar and seal around the pipe.
10. Add additional vent lengths for proper height. Figure
28
11. Apply high temperature sealant to 4” and 7” collars of
vertical vent termination and install.
FP2304
CDV7 top restrictor
3/09
Figure 25 -
Vertical Through-the-Roof
Restrictor (Part #69D3006)
FP304
FP1029
attic insulation shield
firestop spacers
1/28/00 djt




11”
(79 mm)

Joist
Firestop
Spacer
Nails (4)
FP109
Figure 26 -
Place Firestop Spacer(s) and Secure
If there is a room above ceiling level, fire stop spacer must
be installed on both the bottom ad the top side of the ceil-
ing joists. If an attic is above ceiling level an Attic Insula-
tion Shield must be installed. The enlarged ends of the
vent section always face downward.
FP1184
Typical roof/ceiling
support apps.






FP1184
Figure 27 -
Venting Supports
1 +  + 3 + 4 = 70°