3. Specifications
Model
Noise level (50/60 Hz)
External static pressure
Cooling mode:
– 5 °CDB ~ 43 °CDB [23 °FDB ~ 109 °FDB] (0 °CDB ~ 43 °CDB [32°FDB ~ 109 °FDB] with outdoor unit at lower position)
Heating mode:– 20 °CWB ~ 15.5 °CWB [– 4 °FWB ~ 60 °FWB]
Cooling mode: 21 °CDB ~ 43 °CDB [70 °FDB ~ 109 °FDB]
Heating mode:– 12.5 °CWB ~ 20 °CWB [10 °FWB ~ 68 °FWB]
5. Space required around unit
[Fig. 5.0.1] (P.2)
<A> Top view <B> Side view
<C> When there is little space up to an obstruction
A Front B No restrictions on wall height (left and right)
C Air outlet guide (Procured at the site) D Must be open
E Wall height (H) F No restrictions on wall height
(Unit : mm [in])
L1 L2
450 [17-23/32] 100 [3-15/16]
(1) Basic space required
(2) When there is an obstruction above the unit
(3) When inlet air enters from right and left sides of unit
Wall heights “H” of the front and the back sides shall be within total height of
unit.
When wall height “H” exceeds total height of unit, add “h” dimension to L
1 and
L
2 of the Fig. 5.0.1.
“h” = wall height “H’” – total height of unit
(4) When unit is surrounded by walls
Note:
Wall heights “H” of the front and the back sides shall be lower than either
the front or the back panel.
If the panel height is exceeded, add the “h” dimension of the Fig. 5.0.1 to
L
1 and L2.
(Unit : mm [in])
L1 L2
450 [17-23/32] 100 [3-15/16]
Example: When the “h” dimension is 100 mm [3-15/16in],
the L
1 dimension becomes 450 [17-23/32] + 100 [3-15/16] = 550 mm
[21-21/32in].
(5) Collective installation and continuous installation
Space required for collective installation and continuous installation:
When installing several units, provide the space between each block consider-
ing passage for air and people.
Open in two directions.
In case of wall height “H” exceeds total height of unit, add “h” dimension (h =
wall height “H’” – total height of unit) to * marked dimension.
If there is a wall at both the front and the rear of the unit, install up to four units
(Every three units in the case of P168 ~ P234.) consecutively in the side direc-
tion and provide a space of 1000 mm [39-3/8in] or more as inlet space/pas-
sage space for each four units (Every three units in the case of P168 ~ P234).
6. Lifting method
[Fig. 6.0.1] (P.2)
Caution:
Be very careful to carry product.
- Do not have only one person to carry product if it weighs more than 20 kg [46LBS].
- PP bands are used to pack some products. Do not use them as a mean for transportation because they are dangerous.
- Do not touch heat exchanger fins with your bare hands. Otherwise you may cut your hands.
- Tear plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic packaging bag may suffocate children to death.
- When carrying outdoor unit, be sure to support it at four points. Carrying with 3-point support may make outdoor unit unstable, resulting in it falling.
4. Confirmation of parts attached
Total capacity
Model
Quantity
Standard type
Fresh air intake
type
Indoor units
Operation
temperature
PUHY-P72
56 dB<A>
1 ~ 13
PUHY-P96
57 dB<A>
1 ~ 16
PUHY-P108
60 dB<A>
1 ~ 19
PUHY-P126
61 dB<A>
1 ~ 20
PUHY-P144
61 dB<A>
1 ~ 22
0 Pa
50 ~130 %
06 ~ 96
Model
Noise level (50/60 Hz)
External static pressure
Cooling mode:
– 5 °CDB ~ 43 °CDB [23 °FDB ~ 109 °FDB] (0 °CDB ~ 43 °CDB [32°FDB ~ 109 °FDB] with outdoor unit at lower position)
Heating mode:– 20 °CWB ~ 15.5 °CWB [– 4 °FWB ~ 60 °FWB]
Cooling mode: 21 °CDB ~ 43 °CDB [70 °FDB ~ 109 °FDB]
Heating mode:– 12.5 °CWB ~ 20 °CWB [10 °FWB ~ 68 °FWB]
Total capacity
Model
Quantity
Standard type
Fresh air intake
type
Indoor units
Operation
temperature
PUHY-P168
61 dB<A>
1 ~ 24
PUHY-P192
62 dB<A>
1 ~ 24
PUHY-P204
62 dB<A>
1 ~ 24
PUHY-P216
62.5 dB<A>
1 ~ 32
PUHY-P234
63 dB<A>
1 ~ 32
0 Pa
50 ~130 %
06 ~ 96
Model
Model
P72
P96 ~ P108
P126 ~ P234
P72
P96 ~ P108
P126 ~ P234
1
Conduit mounting plate (ø53 [2-3/32])
1 pcs.
5 Tapping screw M4
2 pcs.
2 pcs.
2 pcs.
2
Conduit mounting plate (ø46 [1-13/16])
1 pc.
6 Connecting pipe (Flare)
1 pc.
3
Conduit mounting plate (ø33 [1-5/16])
1 pc.
1 pc.
7 Connecting pipe (Flange)
1 pc.
1 pc.
4
Conduit mounting plate (ø27 [1-3/32])
1 pc.
1 pc.
8 Packing (inside ø23 [29/32],
outsideø35 [1-13/32])
1 pc.
1 pc.
(Unit : mm [in])