Mitsubishi 6G7 Air Conditioner User Manual


 
6G7 ENGINE (E-W) -
Exhaust Manifold & Water Pump
11A-8-2
INSTALLATION SERVICE POINTS
"
A
A
O-RING / WATER PIPE
(1) Wet the O-ring (with water) to facilitate assembly.
Caution
D
Keep the O-ring free of oil grease.
"
B
A
EXHAUST MANIFOLD GASKET
(1) Install gaskets with number
1, 3 and 5 embossed on their
top side to the right bank (exhaust manifold (B) side) and
install thosewith number
2, 4and6 to theleft bank (exhaust
manifold (A) side).
(2) Torque the nuts to 30 Nm.
PWEE9615
E
Dec. 1996Mitsubishi Motors Corporation
6EN0594
O-ring
Water pump
Water inlet pipe
Cylinder No.
Front
Front
Cylinder No.
For right bank
For left bank
7EN0593
71N0010