Mitsubishi Electronics PCH30GK Air Conditioner User Manual


 
OC277-7
SPECIFICATIONS3
Capacity
Moisture removal
Power
Consumption
EER
SEER
HSPF
COP
INDOOR UNIT MODELS
External finish
Power supply
Max.fuse size (time delay)
Min.ampacity
Fan motor
Booster heater
Airflow Hi-Lo
Sound level Hi-Lo
Unit drain pipe O.D. (On a local side)
Dimensions
Weight
OUTDOOR UNIT MODELS
External finish
Power supply
Max.fuse size (time delay)
Min.ampacity
Fan motor
Compressor
Crankcase heater
Refrigerant control
Defrost method
Sound level
Dimensions
Weight
REMOTE CONTROLLER
Control voltage (by built-in transformer)
REFRIGERANT PIPING
Pipe size
Connection
method
Between the indoor
& outdoor units
Cooling *1
Heating *1
Heating *2
Cooling *1
Heating *1
Heating *2
*1
*1
*2
Dry
Wet
W
D
H
Model (type)
W
D
H
Liquid
Gas
Indoors
Outdoors
Height difference
Piping length
Btu/h
Btu/h
Btu/h
Pints/h
kW
kW
kW
V,phase,Hz
A
A
F.L.A.
A
(
kW
)
CFM
CFM
dB
in.
in.
in.
in.
lb
V,phase,Hz
A
A
F.L.A.
R.L.A.
L.R.A.
A
(
W
)
dB
in.
in.
in.
lb
in.
in.
ft
ft
PCH24GK
Model
24,000
27,000[34,000/35,500]
14,800[21,800/23,300]
4.6
2.51
2.46[4.49/4.94]
1.95[3.98/4.43]
9.6
10.3
6.8
3.2
2.2
PCH24GK
20
15
1.1
9.8/10.8<2.0/2.5>
880-710
810-640
48-43
1
51-9/16
26-3/4
10-5/8
87
PUH-24EK
20
16
0.65+0.65
NH33NBD
11.5
54
0.16/0.17<33/39>
55
34-1/4
11-5/8
49-9/16
202
3/8
5/8
PCH30GK
30,000
33,000[40,500/42,500]
20,000[27,500/29,500]
4.3
3.23
3.00[5.25/5.76]
2.58[4.83/5.34]
9.3
10.0
7.0
3.2
2.3
PCH30GK
25
17
1.3
10.8/12.0<2.3/2.8>
51-45
1
101
PUH30EK
30
20
0.75+0.75
NH41NAD
14.0
73
0.16/0.17<33/39>
55
245
Munsell 0.70Y 8.59/0.97
208/230,1,60
Munsell 5Y 7/1
208/230,1,60
Capillary tube
Reverse cycle
With indoor unit
Indoor unit-remote controller: DC12V. Indoor unit-outdoor unit: DC12V
Not supplied (optional parts)
3/4
Flared
Flared
164
165
PCH36GK
35,400
38,000[45,500/47,500]
21,000[28,500/30,500]
6.3
3.60
3.32[5.57/6.08]
2.63[4.88/5.39]
9.8
10.3
7.0
3.4
2.3
PCH36GK
25
17
1.3
10.8/12.0<2.3/2.8>
1,240-990
1,130-880
51-45
1
63-3/4
26-3/4
10-5/8
PUH36EK
1
30
22
0.75+0.75
NH47NAD
17.5
87
0.16/0.17<33/39>
55
38-3/16
13-9/16
49-9/16
246
1/2
PCH42GK
42,000
45,000[52,500/54,500]
23,800[31,300/33,300]
10.3
4.10
3.76[6.01/6.52]
3.00/[5.25/5.76]
10.5
10.3
7.2
3.4
2.3
PCH42GK
25
17
1.3
10.8/12.0<2.3/2.8>
51-45
1
PUH42EK7
40
28
0.8+0.8
ZR42K3PFV
20.4
109
0.16/0.17<33/39>
56
268
7/8
Item
106
NOTES : *1.Rating conditions (cooling)-indoor : D.B. 80˚F, W.B. 67˚F outdoor : D.B. 95˚F, W.B. 75˚F.
(heating)-indoor: D.B. 70˚F, W.B. 60˚F outdoor : D.B. 47˚F, W.B. 43˚F.
*2.Rating conditions (heating)-indoor: D.B. 70˚F, W.B. 60˚F outdoor : D.B. 17˚F, W.B. 15˚F.
*3.Heating capacity and power consumption in [ ] includes booster heater operation at 208/230V.
Operating range
Indoor intake air temperature
D.B. 95˚F, W.B. 71˚F
D.B. 67˚F, W.B. 57˚F
D.B. 80˚F, W.B. 67˚F
D.B. 70˚F, W.B. 68˚F
Outdoor intake air temperature
D.B. 115˚F
D.B. 0˚F *
D.B. 75˚F, W.B. 65˚F
D.B. 17˚F, W.B.15˚F
Cooling
Heating
Maximum
Minimum
Maximum
Minimum
*
In case of the wind baffle is installed.
(In case of the wind baffle is not installed, the minimum temperature will be D.B. 23˚F.)
MODELS : PCH24GK, PCH30GK, PCH36GK, PCH42GK