Master Lock F-64TPG Home Security System User Manual


 
5
F-64TPG TOUCHPAD CONTROLS & INDICATORS
LCD Window – 32 character LCD displays
system status messages, zone
descriptions, system troubles, etc.
STATUS Light. Lights (green) to indicate
that the syst em is ready for arm ing. If a
zone is not secured, the light will be off
and the zone will display in the window. If
a zone has been bypassed, the STATUS
light will blin k while armed.
ARMED Light. Lights (red) to indicate that
the system is armed. If an alarm has
occurred, the ARMED LED will be
flashing.
Alarm Speaker – Will sound a LOUD
steady sweep tone when intrusion is
detected or a dis tinct p ulsati ng ton e f or a
fire alarm condition. Also chirps to
indicate armed AWAY, and provides for
audible voice prompts.
STAY Button – Press once to initiate the
arm Stay sequence. Stay Mode
bypasses all interior zones
simultaneously to allow free movement
within the premises. Hold down for 2
seconds if all zones secure to eliminate
60-second pre-arm delay.
AWAY Button – Press to initiate arm
AWAY sequence when no one is to
remain home. Exit and close garage
door f rom outside the prem ise s. System
will be f ully armed with all perimeter and
interior devices activated.
BYPASS Button – Press to enter the
Bypass Menu, where system functions
are displ aye d i n th e LCD wi nd ow. Pr ess
YES to select the des i red f uncti on; pr ess
RESET to exit. Bypassing a zone
deactivates the zone from the system.
MENU Button – Press to enter Function
Mode, in which available system
functions are displayed in the LCD
window. The desired function is then
selected by pressing the YES button.
Press RESET to exit.
RESET Button – Press to silence Fire
alarms, troubles and exits Function Mode
(see MENU Button).
YES Button – Press to select the desired
function in menus (see MENU Button,
above).
NO Button – Press to answer no to menu
questions and proceed to the next
question (see MENU Button, above).
ENTER Button – Press to accept dis played
value and to move cursor to next
position.
Integral PIR – Used to detect intruders and
your prese nce near th e T ouc h pad d ur i ng
arming and disarming. Do not block.
FIRE Button – Press and hold down for
2 seconds to alert the Central Station of a
fire emergency.
+ AUX Button – Press and hold do wn for 2
seconds to alert the Central Station of a
auxiliary emergency.
Police Button – Press and hold down
for 2 sec onds to alert the C entral Station
of a police emergency.
I-FOB – The I-FOB is a uniquely coded
digital key. Insert the I-FOB into its
keyhole to disarm the system and silence
the siren in case of an alarm.
Slide Plate – Lift to view brief descriptions
of Touchpad buttons and procedures.
Bypass Icon – Appears as a reminder that
zones have been bypassed (by pressing
the BYPASS button). If it is necessary to
bypass any inoperative zones, it is
important to have the zones repaired as
soon as possible.
Fire Icon – Steady indicates a fire alarm
condition. Flashing indicates fire alarm
sounding.
Fire TBL Icon – Indicates a problem on a
fire zone is detected.
System TBL Icon – Indicates a trouble
condition exists on the system. Press
SILENCE to silence sounder and display
the trouble.
1
20
2
3
4
5
6
7
8
9
10
11
12
13
14
16
15
17
18
19
21
22
F-64TPG_OI320A.03_USER_2...
page 5
Friday, September 15, 2006 11:40
Composite