Market Forge Industries Gas Operated Boiler Boiler User Manual


 
1
INSTALLATION INSTRUCTIONS
GAS OPERATED BOILERS
MODELS:
M24G100A - 4SP
M24G200A - 4SP
M36G100A - 4SP
M36G200A - 4SP
M36G300A - 4SP
CAUTION: BE SURE TO READ:
Keep this appliance area free and clear from combustibles.
Do not obstruct the ow of combustion and ventilation air.
Keep this manual for future reference.
This installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
code, ANSI Z223.1-Latest Edition. For installation in Canada, this appliance is to be in accordance with the
current CAN/CGA-B149(.1 or .2) Installation Code for Gas Burning Appliances and Equipment and/or Local
Codes.
This applicance, when installed, must be electrically grounded in accordance with local codes, or in the absence
of local codes, with the National Electric Code, ANSI/NFPA70-Latest Edition. For installation in Canada, All
electrical connections are to be made in accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or
Local Codes.
The boiler and its individual shut off valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressure in excess of 1/2 psig (3.45 k/PA).
The boiler must be isolated from the gas supply system by closing its individual manual shut off valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 k/PA).
The wiring diagram label is located on the inside of the Lift-Off Front Panel.
This product must be installed in a room with adequate air supply.
Do not place any objects on or directly against the unit as to block air openings into the combustion chamber.
Clearances from both combustible and non-combustible construction are 3” (76mm) from side walls, 6” (152mm)
from rear wall. With lower deector plate, shown on page 4, installed this unit is suitable for Installation on Com-
bustible Floors.
This unit is serviceable from the front, do not install in such a manner where a service person cannot remove
front panels.
INSTALLING LEGS:
Some models are shipped without legs. A separate carton will contain the legs. If your model is received this way,
be sure to follow the installation instruction sheet packed with the legs.
LEVELING:
In order for the boiler to drain correctly, it is important to use a level on cabinet top both left and right and front-to-
back. If not level, adjust feet. On compartment cookers, check the interior shelves for level condition.
LOWER DEFLECTOR PLATE:
The lower deector plate must be installed on the boiler. Be sure to follow the installation instructions located on
page 4.