Market Forge Industries Gas Operated Boiler Boiler User Manual


 
22
APPLICATION INSTRUCTIONS
S-2299
APPLICATION INSTRUCTIONS FOR TOTAL CONCEPT CLEANING OF BOILER
SIZE: 1 Gallon PART NUMBER: 20 - 0307
GENERAL NOTES:
Market Forge R has two basic types of boilers; one has
an automatic drain valve, the other has a manual drain
valve. To determine which type you have, open cabinet
doors and you will see a control box with two switches
and an indicator light. The instruction label on the control
box will identify the boiler as being either automatic or
manual. Those boilers designated as being automatic
must be energized in order to close the drain valve.
Total Concept is designed to be used with water between
160°F to 200°F.
Preheating is required on both automatic and manual
boilers to raise the water temperature to the acceptable
range. (160°F to 200°F).
For manual boilers, make certain drain valve is tightly
closed.
On Market Forged boilers manufactured after 8/84; your
unit is equipped with an access plug in the steam header
line. This location should be used to add cleaner/des-
caler to boiler chamber during maintenance.
On Market Forged boilers manufactured before 8/84; ac-
cess to boiler chamber should be gained through either
the vent-rite or the pressure relief valve.
Total Concept is a NSF listed nonfood product. This is
a liquid acid (nonmuriatic) product that works without
fumes, odors, and hazards associated with other harsh
chemicals.
BOILER TREATMENT CLEANING INSTRUCTIONS:
After determining proper location for cleaner/descaler
to be added: Read complete instructions thoroughly; in-
cluding all warning and cautionary statements.
Fig. 1
1. Energize boiler and ll to operating level.
Fig. 2
2. Energize heating circuit to pre-heat unit.
Fig. 3
Fig. 4
3. AUTOMATIC - After unit is pre-heated, cycle the pow-
er switch to the OFF position then immediately back
to the ON position.