25
DVB4136 Direct Vent Gas Fireplace
20012322
Operating Instructions
Glass Information
Only glass approved by CFM Corporation
should be used on this fireplace.
• The use of any non-approved replace
-
ment glass will void all product warranties.
• Care must be taken to avoid breakage of the glass.
• Do not operate appliance with glass front re-
moved, cracked or broken.
• Replacement glass (complete with gasket) is
available through your CFM Corporation dealer
and should only be installed by a licensed quali-
fied service person.
1.
2.
FP444
remove louvre
12/99
Louvre
Glass Panel
FP444
Fig. 45 Remove louvre assembly
top.
Louvre Removal
To remove louvre
assembly top, pull
louvre up and then
lift out. The louvre
assembly bottom
is hinged at the
bottom edge and
swings down. (Fig.
45)
FP771a
DV360/580
GLASS REMOVAL-CLIP
1/27/00 djt
Clamps
Window Frame
Assembly
Glass
Panel
Fireplace Front
FP771a
Glass
Panel
Pull Clamp
Hook
Push Clamp
Handle
Fig. 46 Window frame assembly removal.
Glass Cleaning
It is necessary to clean the glass periodically. During
start-up condensation, which is normal, forms on the
inside of the glass and causes lint, dust and other air-
borne particles to cling to the glass surface. Also initial
paint curing may deposit a slight film on the glass. It
is therefore recommended the glass be cleaned two or
three times with a non-ammonia household cleaner and
warm water (gas fireplace glass cleaner is recommend-
ed). After the initial cleaning process the glass should
be cleaned two or three times during each operating
season depending on the environment in the house.
Clean the glass after the first two weeks of
operation.
Do not clean glass when hot.
Do not use abrasive cleaners.
Do not strike or slam the glass.
Installation of Optional Ceramic Panels
1. Remove glass.
2. Remove glass heat shield located at the top of the
firebox toward the front.
3. Place the rear panel behind the rear log bracket.
4. Slide the right and left panels into place, The right
and left panels will hold the rear panel in place when
positioned properly.
5. Replace the glass heat shield.
6. Place the right and left hearth refractories and bring
them together in the center and slide towards the
front of the unit.
�
Window Frame Assembly Removal
1. Turn the fireplace OFF (including the pilot).
2. If the unit has been operating, allow time for the
components to cool.
3. Remove louvre assembly top.
4. Open the louvre assembly bottom.
5. Release the two clamps along lower edge of the
frame by pulling down on clamp handles. (Fig. 46)
6. Tilt window frame assembly out slightly at the bot-
tom, lift the frame up and away from the fireplace.
7. To replace window frame assembly reverse proce
-
dure.