Lochinvar SNR200-100 Water Heater User Manual


 
OPEN
FRONT
1" MINIMUM CLEARANCE
AROUND HOT WATER
PIPES AND VENT PIPE
Figure 1-2 Alcove Installation - Minimum Required Clearances
1" MINIMUM CLEARANCE
AROUND HOT WATER
PIPES AND VENT PIPE
CLOSED DOOR
VENTILATING
AIR OPENING
VENTILATING
AIR OPENING
*
A
RE
A
O
F EACH OPE
NING
:
1 SQ. INCH PER 1000 BTU PER HOUR INPUT
WITH A MINIMUM OF 100 SQ. INCHES
6"
6"
Figure 1-1 Closet Installation - Minimum Required Clearances
ƽ WARNING
For closet installations, CPVC
material MUST BE used in a closet
structure due to elevated
temperatures. Failure to follow this
warning could result in fire,
personal injury, or death.
9
1 Determine water heater location (continued)
RECOMMENDED SERVICE
CLEARANCES:
Top - 18" (457 mm)
Right Side - 24" (610 mm)
Front - 24" (610 mm)
RECOMMENDED SERVICE
CLEARANCES:
Top - 18" (457 mm)
Right Side - 24" (610 mm)
Front - 24" (610 mm)
Installation & Service Manual
TM
ƽ WARNING
For alcove installations, CPVC
material MUST BE used in an
alcove structure due to elevated
temperatures. Failure to follow this
warning could result in fire,
personal injury, or death.