1. Specification
Cooling Capacity kW
Btu/h.
Heating Capacity ( for Heat Pump models) kW
Btu/h.
Electric Heater capacity kW
Btu/h.
Power Input Cooling/Heating W
Running Current Cooling/Heating A
Starting current Cooling/Heating A
Electric Heater Current A
EER W/W
Btu/h.W
COP W/W
Power Supply Ø / V / Hz
Power Factor %
Air Flow Rate Indoor,Max m
3
/min(CFM)
Outdoor,Max m
3
/min(CFM)
Moisture Removal l/h
Sound Level Indoor,H/M/L dB(A)±3
(SoundPressure,1m) Outdoor,Max dB(A)±3
Refrigerant & Charge g(oz)
Compressor Type
Model
Motor Type
Oil Type
Oil Charge cc
O.L.P Name
Fan Type(In/Out)
Motor Type(In/Out)
Motor Output(In/Out) W
Power Supply Cable (Power Cord) No.*mm
2
Dimensions ( W * H * D) mm
inch
Net Weight kg(lbs)
Tool Code(Chassis)
Features Temperature Control
Energy Saver Mode
Prefilter(washable/anti-fungus)
Plasma Filter
Steps, Fan/Cool/Heat
Airflow Direction Control(up&down)
Airflow Direction Control(left&right)
Remote Controller Type
Setting Temperature Range Cooling
Heating
Auto Operation (Micom Control)
Panel Touch Type
Timer
Air Discharge
Air-Ventilation
Defrost Control
Hot Start
Look
Cabinet Type(Chassis Type)
Special Function
Model
LP121CEM-Y8
3.28 3.37
11300 11500
--
--
3.1 3.5
10500 11900
1045 1065
5.0 4.6
--
14.9 15.2
3.16 3.16
10.8 10.8
--
1 / 208 / 60 1 / 230 / 60
97.7 98.0
11(390)
-
1.5
51/-/47
63
R22, 585(20.6)
Rotary(Non Tropical)
QK145KBA
PSC
SUNISO 4GSI or NM56M
280
MRA 12054 - 12026
Cross Flow Fan / Axial Fan
4 Poles
18.4/60
3 * 2.1
1066*406*505
42*16*19-7/8
49.0(108.0)
YA
Thermistor
O
O
-
2/2/2
Manual
-
Wall Thermostat
54˚F ~ 86˚F(12.2˚C ~ 30˚C)
-
-
Mechanical controls
-
Rear
O
-
-
L - Look
Slide In-Out
Electric Heater
Note:
O
: Applied, - : No relation
*
For circuit breaker rating, please confirm to local standards wherever necessary.
Some of functions are slightly different depending upon models.
The specification may be subject to change without prior notice for purpose of improvement.