Lennox International Inc. G61MP Series Units Gas Heater User Manual


 
Page 4
G61MP Gas Furnace
The G61MP category IV gas furnace is shipped ready for
installation in the upflow, downflow, horizontal left air dis-
charge or horizontal right air discharge position. The fur-
nace is shipped with the bottom panel in place. The bot-
tom panel must be removed if the unit is to be installed in
upflow applications with bottom return air. The bottom
panel must also be removed and discarded in all downflow
or horizontal applications.
The furnace is equipped for installation in natural gas ap-
plications. A conversion kit (ordered separately) is re-
quired for use in propane/LP gas applications.
The G61MP can be installed as either a Direct Vent or a
Non−Direct Vent gas central furnace.
NOTE − In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors. In
Non−Direct Vent installations, combustion air is taken from
indoors and flue gases are discharged outdoors. See figure
2 for applications involving roof termination.
FIGURE 2
DIRECT VENT INSTALLATION NON−DIRECT VENT
INSTALLATION
EXHAUST
OUTLET
COMBUSTION
AIR INTAKE
OUTSIDE OF
HOUSE
CONDENSATE
DRAIN
EXHAUST
OUTLET
G61MP
COMBUSTION
AIR INTAKE INSIDE
OF HOUSE
G61MP
CONDENSATE
DRAIN
Shipping and Packing List
Package 1 of 1 contains
1 − Assembled G61MP unit
1 − Bag assembly containing the following:
3 −Screws
3 −Wire nuts
1 −Snap bushing
1 −Snap plug
1 − Wire tie
1 −Condensate trap
1 −Condensate trap cap
2 −2" diameter vent / intake plugs
1 −3" diameter cabinet plug (intake)
1 −2" diameter debris screen
1 −Logo sticker (for use in downflow applications)
NOTE − G61MP−48C−110, G61MP−60C−110 and
G61MP−60C−111 units also include a 2" diameter PVC
street elbow, which is shipped on the blower deck in the
heating compartment. G61MP−60D−135 units are shipped
with a 3" to 2" PVC reducing elbow.
Canadian Installations Only − Replace the provided 2"
street elbow shipped with the G61MP−48C−110,
G61MP−60C−110 and G61MP−60C−111 units with 2" street
elbow Y0162. Replace the provided 3" X 2" reducing elbow
shipped with the G61MP−60D−135 units with 3" X 2" reduc-
ing elbow 40W22. Y0162 and 40W22 meet B149 vent re-
quirements.
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
The following items may also be ordered separately:
1 − Thermostat
1 − Propane/LP changeover kit
DANGER
Danger of explosion.
There are circumstances in which odorant used with
LP/propane gas can lose its scent. In case of a leak,
LP/propane gas will settle close to the floor and may
be difficult to smell. An LP/propane leak detector
should be installed in all LP applications.
Safety Information
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
CAUTION
As with any mechanical equipment, personal injury
can result from contact with sharp sheet metal
edges. Be careful when you handle this equipment.
Use only the type of gas approved for use with this furnace.
Refer to unit nameplate.
G61MP units are CSA International certified to ANSI
Z21.47 and CSA 2.3 standards.
In the USA, installation of gas furnaces must conform with lo-
cal building codes. In the absence of local codes, units must
be installed according to the current National Fuel Gas Code
(ANSI-Z223.1/NFPA 54). The National Fuel Gas Code is
available from the following address:
American National Standards Institute, Inc.
11 West 42nd Street
New York, NY 10036