Kenmore 153.33288 Water Heater User Manual


 
Installation Instructions (cont'd)
Installation Checklist
BEFORE OPERATING:
Check the gas lines for leaks•
a. Use a soapy water solution• DO NOT test for gas leaks
using a match or open flame.
b. Brush the soapy water solution on all gas pipes, joints and
fittings•
c. Check for bubbling soap. This means you have a leak.
_lhrn OFF gas and make the necessary repairs.
d. Recheck for leaks•
e. Rinse off soapy solution and wipe dry.
ls the new temperature-pressure relief valve properly installed
and piped to an adequate drain? See "_l_mperature-Pressure
Relief Valve" section•
Are the cold and hot water lines connected to the water
heater correctly? See "Water Piping" instructions in the
"Installation Instructions" section.
ls the water heater completely filled with water? See "Filling"
instructions in the "Installation Instructions" section.
Will a water leak damage anything? See the "Facts to
Consider About the Location" section.
ls there proper clearance between the water heater and any-
thing that might catch fire? See the "Facts to Consider About
the Location" section.
Do you have adequate ventilation so that the water heater
will operate properly? See "Combustion Air and Ventilation"
in the "Installation Instructions" section.
ls the draft hood vent piping properly secured? See "Venting"
instructions in the "Installation Instructions" section.
ls there proper clearance between the vent pipe and anything
that might catch fire. See Ventmg mstructtons m the
"Installation Instructions" section.
PIPE TO
OUTDOORS
HOT
VALVE
DRIP LE(
[Sediment trap)
PIPE I
GAS
SUPPLY
SHUTOFF
VALVE
PRESSURE
RELIEF VALVE
PiPE
(Do not cap or plug)
g
ls the vent pipe properly sloped and does the vent terminate
outdoors• See Venting mstructmns m the Installatmn
Instructions section.
Do you need to call your gas company to check the gas pipe
and its hookup?
CHECK FOR LEAKS
Be sure to check all your gas pipes for leaks before operating
your water heater. Use a soapy water solution, not a match or
open flame. Check the factory gas fittings after the main burner
is turned "ON". Use a soapy water solution for this, too.
SLII'I_&BLI:FOR WATER (PGTABI.E)
HEATING ONLY
EGt_PPED
F_ k_PLt¢ RECOVERy _IAL Nt/MS_
I I I
GAS BTU_ GALPAR
MAXIMU_ HyD_TATIC GAS pRE_RE IN W C _N T_NG *
,so I I
PNI WC WC WC
AUTOMATIC STORAGE WATER HEATER
ELECTRICAL RATING: VOLTS 115!HZ60/AMPS 2
MODEL RATING PLATE
25