Karcher KMR 1250 D Vacuum Cleaner User Manual


 
English User Instructions KMR 1250 D
44
Safety information
which must be observed when handling batteries.
Comply with the user instructions and ensure that these are displayed at the
charging station. Before the operator carries out any work on batteries, he/she
must have received proper instruction from a suitably qualified person.
Wear safety goggles and protective clothing when working on batteries. Ob-
serve accident prevention regulations, as well as DIN VDE 0510, VDE 0105
Part 1.
Smoking is forbidden!
Make sure that there are no naked flames, other source of heat or sparks in
the proximity of the battery, otherwise there is a danger of explosion or fire.
If electrolyte comes into contact with skin or eyes, rinse the affected area with
plenty of clean water. The metal parts of battery cells are permanently live.
Therefore do not place any tools or other objects on top of the battery.
Explosion and fire hazard! Avoid short-circuits.
Warning! The metal parts of battery cells are permanently live. Therefore do
not place any tools or other objects on top of the battery.
Electrolyte is highly corrosive. Under normal operating conditions it is not
possible for anything to come into contact with the electrolyte. If the battery
housing is destroyed, the bound electrolyte that leaks out is just as corrosive
as liquid electrolyte.
Return to manufacturer!
Exhausted batteries bearing this symbol are a re-usable resource which
should be recycled accordingly. Exhausted batteries that are not intended to
be recycled must be disposed of as hazardous waste in compliance with all
relevant regulations.
Note:
We recommend using the automatic battery charger (part
number 6.654-116) for starter batteries. Only use a battery
charger having a mark of conformity!
Only use a battery charger with a certification mark!
Only undertake the charging procedure in dry, weather-
protected areas.
n Bring machine to a stop, remove ignition key
n Tilt the seat forward and open the unit cover
n Connect the positive (battery) post (+) with the battery
charger (red clip)
n Connect the negative (battery) post (-) with the battery
charger (black clip)
n Connect the battery charger to the network and switch on
as necessary. Charging period according to
manufacturer’s specifications.
Charging the battery
Checking the level of
electrolyte in the battery
Note: This only affects batteries which are not absolutely
maintenance free.
Check the level of electrolyte in batteries filled with acid.
Make sure the battery is fully charged before you carry out
the check. If required:
n Top up each cell with distilled water until the lead plates
are covered by approx. 1 cm of liquid.