Jotul GF 200 DV Stove User Manual


 
23
With proper care and maintenance, your Jøtul
gas stove will provide you with many years of
service. If you experience any problems with Jøtul
GF 200 DV, contact your authorized Jøtul dealer for
assistance.
Fill out the Maintenance Record form on the
next page and keep it up to date. It will provide
useful information of service activity to help you
and your dealer keep your stove in top condition.
RETAIN THIS MANUAL FOR REFERENCE
AND MAKE IT AVAILABLE TO ANYONE
USING OR SERVICING THE STOVE.
Maintenance
The GF 200 DV Lillehamer gas stove and its venting
system should be inspected before use and at least
annually by a qualified service technician.
IMPORTANT:
ALWAYS TURN OFF THE GAS SUPPLY TO
THE STOVE BEFORE ANY SERVICE WORK
IS PERFORMED ON THE STOVE.
General cleaning: The firebox should be vacuumed
out annually to remove any surface build up. Be
sure to vacuum or wipe off the pilot assembly and
burner orifice and burner tube. Also, when vacu-
uming the log set, be sure to handle it carefully as
it is very fragile.
Gasket inspection: It is important that the glass
gasket be inspected at least annually. Examine the
rope gasket for signs of deterioration and make
sure the gasket has a positive seal. This is impor-
tant to prevent combustion gases from escaping
into the room. Replace the gasket if necessary,
refer to the replacement parts list on page 25.
Always replace any damaged or broken parts
with JØTUL AUTHORIZED PARTS ONLY. These are
available through your Jøtul dealer. Never use any
substitute parts on your Lillehammer Direct Vent
stove.
WARNING:
OBSERVE CAUTION NEAR THE
GLASS. THE GLASS PANEL MAY SHATTER
UNEXPECTEDLY IF STRUCK WITH AN
OBJECT. ALWAYS HANDLE THE GLASS
PANEL WITH CARE. WHEN SERVICING THE
STOVE ALWAYS PULL THE GLASS ASSEM-
BLY STRAIGHT UP FOR REMOVAL.
Glass Front
Do not operate the Lillehammer gas stove with the
glass front removed, cracked or broken. Replace-
ment of the glass should be done by a licensed or
qualified service person. Only remove glass for
routine service. Always handle glass carefully.
Figure 27. Glass removal.
Glass and Gasket Replacement
1. Using a nail punch inserted into the perf holes,
carefully pry the two glass retainer tabs back. See
fig. 27.
2. Peel away all remnants of the old gasket material
and clean any adhesive residue off the glass.
3. Peel the paper backing off the replacement
gasket to expose the adhesive.
4. Apply the gasket to the panel, wrapping the
adhesive side down around the panel edge. See
fig. 28.
5. Insert the gasketed glass panel into the frame
and use the nail punch to bend the retainer tabs
over the edge.
Bend Tab back
Figure 28. Glass gasket replacement.