Jotul GF3 DVII Stove User Manual


 
The Jøtul GF3 DVII Allagash is a Direct Vent wall
furnace and is designed as a sealed combustion, air
circulating gas appliance for residential applications.
The following vent components are approved for use
with the Jøtul GF3 DVII, vented directly to the outside
of the house:
Simpson Dura-Vent 6 5/8" X 4" GS pipe
Security Direct Vent 6/4 vent pipe
Amerivent 6/4 vent pipe.
The Jøtul GF3 DVII Allagash gas stove is designed
to operate on NATURAL GAS or PROPANE only. It
manufactured and shipped prepared to burn Natural
Gas. For safe and efficient operation the stove is
equipped with a millivolt gas control valve with a piezo
ignitor. Electrical power is only required when operat-
ing the OPTIONAL forced air blower.
Rear Exit
Centerline
24 3/4
629 mm
13 1/4
337 mm
Top Exit
27 3/4
705 mm
28
711 mm
22 3/4
578 mm
2
Specifications
Input Rates
Natural Gas
26,000 BTU/hr. maximum input
20,000 BTU/hr. minimum input
Propane
26,000 BTU/hr. maximum input
20,000 BTU/hr. minimum input
Minimum Inlet Pressure:
Natural Gas: 5.0 WC (1.25 kPa)
Propane: 11.0 WC (2.75 kPa)
Manifold Pressure: MIN MAX
Natural Gas: 2.0 WC (.85 kPa) 3.5 WC (.85 kPa)
Propane: 6.4 WC (1.60 kPa) 10.0 WC (2.50 kPa)
Steady State Efficiency: 82%
A.F.U.E.: 73%
Piezo Ignitor / Standing Pilot