Correct gas pressure is essential for efficient and
safe operation of the Allagash gas stove. It is impor-
tant that the correct gas pressure be established at
the time of the installation. For more details see the
Gas Pressure section of this manual.
ALWAYS REFER TO THE LIGHTING
INSTRUCTIONS ON THE INSIDE BACK
COVER OF THIS MANUAL AND ON THE
BACK OF THE RATING PLATE.
9. Change the pilot orifice. From within the firebox,
pull the spring clip back and remove the Pilot Head
from the Pilot Base. Use the 4 mm hex key to
remove the old Pilot Orifice from the base (coun-
terclockwise). See Fig. 13.
Replace with the appropriate pilot orifice.
#51 for natural gas
#30 for propane
Be certain the orifice is securely tightened.
Replace the Pilot Hood into the base.
12. Replace the Variable Regulator: Using a Torx T-20
screwdriver, remove the three specialty screws
from the front of the valve regulator. See Fig. 14.
13. Remove the regulator tower and the old black
gasket.
14. Ensure that the new gasket is properly positioned
and install the new variable regulator tower.
Tighten screws securely. Apply the small valve
label to the valve body where it will be easily seen.
15. Reinstall the Burner Tube (13, pg. 22), Air Divider
(15), Log Support (14), and Log Set. WHEN REIN-
STALLING THE BURNER TUBE, BE SURE THE TUBE
IS PULLED FORWARD IN THE MOUNTING HOLES.
SECURE WITH THE TWO 1/4 SCREWS.
16. Apply the two conversion labels to the stove and
rating plate so that they can be seen by anyone
servicing the stove.
17. Reassemble the stove, open the gas supply and
check for leaks using a 50/50 soapy water solu-
tion. NEVER USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
Pilot Hood
Pilot Base
Pilot Orifice
Figure 13. Removing the Pilot Hood and Pilot Orifice.
Figure 14. Regulator Tower and gasket.
Screws
Regulator Tower