Jotul GF300 BV Stove User Manual


 
7
Stove and Vent Clearance
Requirements
Minimum Clearances from the Stove
to Combustibles See figs. 2-3.
Rear: 2” (51 mm) - measured from Draft Hood
Ceiling: 32 1/4” (819 mm) - measured from stove top
Corner: 3” (76 mm) - measured from stove top
Sides: 3” (76 mm - measured from stove top)
Minimum Clearances from the Vent Pipe to
Combustibles
Horizontal Run:
Top: Off the top of the pipe 2” (50 mm)
Sides: Off the sides and bottom 2” (50mm)
Vertical Run:
All sides: 1” (25 mm)
All vent components must be installed in accordance
with the manufacturer’s instructions and within the
terms of their listing. Refer to the manufacturer’s
instructions for approved clearances from the vent pipe
to combustible materials.
Minimum Alcove Dimensions
Maintain clearances to combustibles as noted above.
Width: 36” (914 mm)
Depth: 24” (610 mm)
Height: 61” (1550 mm)
Figure 3. Vent adaptor centerline at minimum clearance
to corner walls.
Figure 4. Mantel and Trim specifications -
Stove installed flush with fireplace face.
Stove shown with standard legs. With Short Legs, subtract 2 1/4” (51 mm)
from the clearances indicated below.
Figure 4a. Mantel specifications -
Stove recessed into fireplace no more than 6 1/2”.
Mantel Clearances -
HEARTH
11 3/4
(298 mm)
11 3/4
(298 mm)
34
(864 mm)
3
(76 mm)
3
(76 mm)
3”
(76 mm)
2”
(51 mm)
To Rear Wall
Figure 2. Parallel Installation Clearances.
3”
(76 mm)
11.5
9.5
7.5
5.5
Max. Mantel Depth
Min. Mantel Depth
27 3/4
705 mm
Max. Top Trim
Depth = 1
50 3/4
1289 mm
11
(266 mm)
1
52 1/4
1327 mm
53 3/4
1365 mm
55 1/4
1403 mm
56 3/4
1441 mm
3.5
27 3/4
705 mm
No Top Trim
38 1/4
972 mm
Mantel Depths
as in Fig.4.
39 3/4
1010 mm
41 1/4
1047 mm
44 1/4
1124 mm
42 3/4
1086 mm
Max.
6 1/2
165 mm
Mantel Sheild:
Min. 24 ga. steel
26 wide on 1
spacers