Jotul GF300 BV Stove User Manual


 
10
Approved B-Vent Configurations
NOTE:
Installation at
altitude greater
than 2000’
requires
minimum 12 ft.
vertical rise from
Draft Hood.
NOTE:
Installation at
altitude greater
than 2000’
requires
minimum 12 ft.
vertical rise from
Draft Hood.
Listed B-Vent
termination
cap required.
Maximum total
horizontal offset
anywhere in
venting
configuration is
4 feet.
Max. Four, 45°
or Three, 90°
Elbows
Minimum
chimney height
from Draft Hood
is 7 feet.
Maximum
chimney
height off
Draft Hood is
35 feet.
Minimum
chimney
height off
Draft Hood is
7 feet.
Listed B-Vent
Termination Cap
required.
NOTE:
Installation at
altitude greater
than 2000’
requires
minimum 12 ft.
vertical rise from
Draft Hood.
NOTE:
Installation at
altitude greater
than 2000’
requires
minimum 12 ft.
vertical rise from
Draft Hood.
Maximum total
horizontal
anywhere in
venting
configuration
is 4 feet.
Listed B-Vent
Termination
Cap required.
Minimum
chimney height
from Draft Hood
is 7 feet.
Max. Four, 45°
or Three, 90°
Elbows
Figure 10.Figure 9.
Figure 8.
Figure 7.
Maximum
horizontal
offset
anywhere in
venting
configuration
is 4 feet.
Listed B-Vent
termination cap
required.
Minimum
chimney height
from Draft Hood
is 7 feet.