Honeywell C7015A Smoke Alarm User Manual


 
C7015A
SPECIFICATIONS
l
ORDERING INFORMATION
Specifications
SUPER
TWELINE
MODELS
SUPER TRADELINE models offer features not
available
on
TRADELINE or standard models, and are designed to
replace a wide range of Honeywell and competitive
controls. SUPER TRADELINE models are selected and
packaged to provide ease of stocking, ease of handling,
and maximum replacement value. Specifications of
SU-
PER TRADELINE models are the same as those of
standard models except as noted below.
SUPER TRADELINE MODEL AVAILABLE:
C7015A1126-with
48 in.
[1.22
m]
leadwires; includes
104662DLead
SulfidePhotocell,
110634A
Bushing with
FocusingLens,
105134GrificePlate,
105061
HeatBlock,
and
390427A
Reducer Bushing.
SUPER TRADELINE FEATURES:
l
Gritice
plate (with
.125
in.
[3.175
mm] diameter
hex-
agonal orifice) for reducing the detector field-of-view.
=
Heat block for insulating the detector
from
sight pipe
temperatures higher than
125’
F
[52”
C]
and up to
250”
F
[
121” C].
l
Reducer bushing for mounting the detector on a
l/2
in.
sight pipe; specifically, for replacing
FireyeW
lead
sulfide
inframd
flame detectors.
l
SUPER TRADELINE pack with cross reference label
and special Instruction sheet.
STANDARD MODELS
MODELS: See Table 6 for flame safeguard controls and
associated amplifiers.
DETECTOR
RESPONSE: Responds to infrared radiation
with wavelengths between 0.75 and 1 .O micron.
LEAD SULFIDE PHOTOCELL: Photoconductor
resis-
tance
decreases as incident radiant energy increases.
AMBIENT TEMPERATURE RATING:
125’
F
[52”
C]
maximum at the lead sulfide photocell.
MOUNTING:
C7015A
Mount-knurled collar with
3/4-14
NPSM in-
ternal
threads for mounting on a standard
3/4
in. pipe
(see fig. 1).
104662DLeadSulfidePhotocell-twoleadsforinserting
into socket in
C7015A
(see Fig. 8).
TABLE l-MODELS AVAILABLE.
With
0.125 in.
[3.175
mm] diameter hexagonal orifice to
reduce
the detector field of view.
%
insulate the detector from sight
pipe
temperatures higher than
125’
F
[52”
C]
and up to
250’
F
[121°
Cl.
To
mount the detector on a l/2 in. sight pipe, specifically to replace
Fireye
TM
lead sulfide infrared flame detectors.
Order Information
When purchasing replacement and modernixation products from your Authorized Flame Safeguard Distributor or Wholesaler, refer to the
TRADELINE@
Catalog or price sheets for complete ordering number, or
specify-
1.
Grder nwnber, SUPER TRADELINE. if desired.
2.
4. Replacement parts, if desired.
Length of leadwires
(30,48. or 96 in. [0.76.1.22, or 2.44 m].
5. Accessories, if desired.
3.
Lead sulfide cell order number
104662D.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1.
Your local Honeywell Residential and Building Controls Division Sales Office (check white pages of phone directory).
2.
Residential and Building Controls Division Customer Satisfaction
Honeywell Inc., 1885 Douglas Drive North
Minneapolis. Minnesota 554224386 (612) 542-7500
(In Canada-Honeywell
Liited/Honeywell
Limitee, 740 Ellesmere Road, Scarborough, Ontario
MlP
2V9)
International sales and
service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan Mexico,
Netherlands, Spain Taiwan, United Kingdom, U.S.A.