Mechanics of Programming
Data Field Programming Procedures (You must use a 2-line Alpha display keypad)
Task Procedure
Entering Program Mode A) Press both [
∗
] and [#] at the same time within 50 seconds after power is applied
to the control, OR
B) After power-up, enter [Installer code (4-1-1-2)] + 8 0 0.
(method “B” is disabled if you exit the program mode using
∗
98)
Go to a Data Field Press [
∗
] + [Field Number] (for example,
∗
21).
A display of “EE” or “Entry Error” means you have entered a nonexistent field.
Simply re-enter [
∗
] plus a valid field number.
Entering Data When the desired field number appears, simply enter the digits required. The
keypad beeps three times after the last digit is entered and automatically displays
the next data field in sequence.
If entering less than the maximum digits available (e.g., phone number field),
enter the desired digits, then press [
∗
] to end the entry.
Review a Data Field Press [#] + [Field Number]. Field data is displayed, but no changes can be made.
Deleting an Entry Press [
∗
] + [Field No.] + [
∗
] (applies only to phone number, account number, and
pager character fields).
Menu Mode Programming (∗
∗∗
∗56, *57, ∗
∗∗
∗58, ∗
∗∗
∗79, ∗
∗∗
∗80, ∗
∗∗
∗81, ∗
∗∗
∗82)
Entering Menu Mode
Press [
∗
] + [Menu Mode No.] (for example,
∗
56) while in Program Mode. The
Alpha display keypad displays the first of a series of prompts.
After making the appropriate entry, press the [∗] key to accept the entry and
continue to the next prompt.
Loading Factory Defaults/Initializing for Download
To Load Default Entries Press ∗97 while in Program Mode. This resets all data fields to the default
values shown on the Program Form. Use
∗
97 only if you wish to return to the
original factory-programmed defaults. Do not press ∗97 to load defaults if any
programming has been done previously—data already programmed into the
system will be changed!
To Initialize Download ID Press ∗96 while in Program Mode. This initializes the system for
downloading and resets all the subscriber account numbers and CSID.
Exiting the Programming Mode
Prevent installer code reentry Press ∗98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if
∗
98 was
used to exit, you must first power the system down. Then power up again,
and press [∗] and [#] at the same time, within 50 seconds of powering up.
See field *88 for other Program mode lockout options.
Allow installer code reentry Press ∗99. Exits Program Mode and allows re-entry by method A or B above.
3-5