Honeywell 6160EX Garage Door Opener User Manual


 
Testing the System
A test function is available which allows a user to manually test the
sensors and alarm sounders on the system. This test is carried out as
follows:
From normal Day mode;
1. Type in the user code.
2. Press 5 (Test)
3. The system will ring the outside bells for 5 seconds and switch on
the strobe light. The strobe light will stay on for the duration of the
test.
4. When the bells switch off the system enters walk test mode to
allow testing of the sensors.
5. Activate each detector in turn. As each detector is activated, the
keypads will beep twice and the zone number will be shown on the
display. When several detectors have been activated, the display
will scroll through all the activated zone numbers.
6. After activating all the detectors, check to make sure all the
corresponding zone numbers are displayed.
7. To end the test, type in the user code again. The strobe light will
switch off.
Note: The Test mode will not operate if there is a fault condition
present.
15