Honeywell 2-Partitioned Security System Home Security System User Manual


 
9
Partition-Specific Fields
(Duplicate this page for each partition in the installation.)
To program these fields,
1. Press *91 to select a partition.
2. Enter a partition-specific field number (ex. *09).
3. Make the required entry.
4. Repeat steps 1-3 for the other partition in the system.
PARTITION #____ PROGRAM FIELDS
1st Page Fields
*09 ENTRY DELAY #1 [02] |
00, 02-15 times 15 seconds.
Maximum 03 for UL Listed installations.
*10 EXIT DELAY #1 [04] |
00, 03-15 times 15 seconds.
Maximum 04 for UL Listed installations.
*11 ENTRY DELAY #2 [06] |
00, 02-15 times 15 seconds.
Maximum 03 for UL installations.
*12 EXIT DELAY #2 [08] |
00, 03-15 times 15 seconds.
Maximum 04 for UL installations.
*13 ALARM SOUNDER DURATION [04] |
01-15 times 2 minutes.
Must be minimum 16 minutes for UL installations.
*16 CONFIRMATION OF ARMING DING [0]
1=enable; 0=disable.
Must be "1" for UL installations.
*22 KEYPAD PANIC ENABLES [001]
1=enable; 0=disable 995 996 999
*23 MULTIPLE ALARMS [1]
1=yes; 0=no. Must be 1 for UL installations.
*29 QUICK ARM [1]
1=yes; 0=no
*32 PRIM. SUBS. ACCT # | | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
*38 PREVENT ZONE XX BYPASS [00] |
001-64; 000 if all zones can be bypassed
*39 ENABLE OPEN/CLOSE REPORT [1]
FOR INSTALLER CODE
1=enable; 0=disable
*84 SWINGER SUPPRESSION [03] |
01-15 alarms; Must be "00" (disabled) for UL installations.
*85 ENABLE DIALER REPORTS FOR PANICS & DURESS
1=enable; [0=disable]
995
996
999
Duress
*87 ENTRY WARNING [1]
1=continuous; 0=3 beeps
*88 BURG. ALARM COMM. DELAY [0]
1=16 seconds; 0=no delay. Must be "0" for UL installations.
*90 SEC. SUBS. ACCT # | | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
2nd Page Fields
1*43 PERM. KEYPAD BACKLIGHT [0]
1=enable; 0=disable When disabled, display lights when
any key is pressed, and turns off after period of keypad
inactivity.
1*45 EXIT DELAY SOUNDING [0]
1=enable; 0=disable. Produces quick beeping during exit
delay if enabled.
1*47 CHIME ON BELL 1 [0]
1=enable; 0=disable
1*52 SEND CANCEL IF ALARM + OFF [0]
1=no restriction; 0=within Bell Timeout period only
1*76 ACCESS CONTROL RELAY FOR PART.[00] |
Relay will be pulsed for 2 seconds whenever code + [0] is
pressed. Enter 00-08; 00=none. Must be "00" for UL installs.
3rd Page Fields
2*18 ENABLE GOTO FOR THIS PARTITION [0]
1=Allow log-on from other partitions; 0=disable
2*20 ENABLE J7 TRIGGERS BY PARTITION [1]
0=disable; 1=enable for
SUMMARY OF PROGRAMMING COMMANDS
To enter program mode, enter installer code + [8] + [0] +
[0]
To set standard defaults, press *97
To change to next page of program fields, press *94
To return to previous set of fields, press *99
To erase account and phone number field entries,
press [*] + field number + [*]
To assign zone descriptors, press #93 + follow menu
prompts
To add custom words, press #93 + follow menu prompts
To enter Installer's Message, press #93 + follow menu
prompts
To exit program mode, enter *99 OR *98: *99 allows re-
access to programming mode by installer code. *98
prevents re-access to programming mode by installer
code.