Honeywell 2-Partitioned Security System Home Security System User Manual


 
8
1*58 5800 RF BUTTON FORCE ARM [0]
Enter "1" to enable. If a zone is faulted after pressing button,
keypad will beep once. Pressing the button again within 4
sec. bypasses the zone. Enter "0" to disable.
Must be "0" for UL installations.
1*60 ZONE 5 AUDIO ALARM VERIFICATION [0]
Enter 1 If 2-way audio (AAV) is being used; Enter 0 if it is
not.
Must be "0" for UL installations.
1*66 SILENCE BELLS DURING AAV [0]
Enter 1 to alarm sounders during AAV session.
Enter 0 to have alarm sounders continue to sound during
AAV session. Must be 0 for UL installations.
1*70 EVENT LOG TYPES
[1 0 0 0 1]
Alarm
Chk
Byp
O/C
Syst
1=enable; 0=disable
1*71 12/24 HOUR TIME STAMP FORMAT [0]
0=12 hour; 1=24 hour
1*74 RELAY TIMEOUT XXX MINUTES [000] | |
Enter the relay timeout, 000-127 in multiples of 2 minutes,
desired for #93 Menu Mode Relay Programming output
command "56."
1*75 RELAY TIMEOUT YYY SECONDS [000] | |
Enter the relay timeout, 000-127 seconds for #93 Menu
Mode Relay Programming command "57."
1*76 ACCESS CONTROL RELAY [00] |
Relay will be pulsed for 2 seconds whenever code + [0] is
pressed. Enter 00-08; 00=none.
Must be "00" for UL.
3rd Page Programming Fields (press *94)
2*00
NUMBER OF PARTITIONS [1]
Enter 1-2
2*01 DAYLIGHT SAVING TIME [04, 10] | |
START/END MONTH Start End
00-12; if no daylight saving time, enter 00,00
2*02 DAYLIGHT SAVING TIME [1, 5] |
START/END WEEKEND Start | End
Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last;
6=next to last; 7=3rd from last [1,5]
2*17 NUMBER OF CODES PER PARTITION
[0] | |
Enter 01-69 for each partition. The total must not exceed 70.
2*18 ENABLE GOTO FOR THIS PARTITION [0]
1=Allow log-on from other partition; 0=disable
2*19 USE PARTITION DESCRIPTORS [0]
0=disable; 1=enable
2*20 ENABLE J7 TRIGGERS FOR PARTITION [1]
0=disable for displayed partition; 1=enable for displayed
partition
2*21 ENABLE SUPERVISION PULSES FOR LRR
TRIGGER OUTPUTS [000]
| |
Used for supervised connection to 7920SE. F B P
Enter 0 to disable or 1 to enable the listed outputs.
F= Fire; B= Burglary; P= Silent Panic/Duress.
Must be 1 for UL. Installations.
SUMMARY OF PROGRAMMING COMMANDS
To enter program mode, enter installer code + [8] + [0] +
[0]
To set standard defaults, press *97
To change to next page of program fields, press *94
To return to previous set of fields, press *99
To erase account and phone number field entries,
press [*] + field number + [*]
To assign zone descriptors, press #93 + follow menu
prompts
To add custom words, press #93 + follow menu prompts
To enter Installer's Message, press #93 + follow menu
prompts
To exit program mode, enter *99 OR *98: *99 allows re-
access to programming mode by installer code. *98
prevents re-access to programming mode by installer
code.