Honeywell 2-Partitioned Security System Home Security System User Manual


 
14
PROMPT
EXPLANATION
ENTER ZONE NO.
00 = QUIT 11
The system now returns to the ENTER ZONE NO. prompt for the next zone.
When all zones have been programmed, enter 00 to quit.
After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in
the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information
(zone number, zone type, etc.) relevant to that device.
When you have finished programming all zones, test each using the systems Test Mode. Do not use the
Transmitter ID Sniffer Mode. The system checks only for transmission of one zone on a particular
transmitter, NOT the zones assigned to each additional loop, and also does not verify polling loop type
zones.
Expert Mode Zone Programming
Expert mode allows you to program zones using the minimum number of screens and keystrokes.
Enter the Programming mode with [Installer Code] + [8] [0] [0]
Before programming your zones, do the following:
1. Program field 200: Number of Partitions.
2. Enable your RF Receiver in Device Programming menu mode.
To program your zones, press 93 to display the "ZONE PROG?" prompt. Enter 0 (NO) to each prompt until the EXPERT
MODE? prompt appears.
PROMPT
EXPLANATION
EXPERT MODE?
1 = YES 0 = NO 0
Press 1 to enter Expert mode.
SET TO CONFIRM?
0 = NO 1 = YES 0
This prompt appears once upon entering Expert Mode.
If you select Yes, Confirmation prompts will be displayed after the devices Serial and Loop numbers have
been entered later.
Zn ZT P RC In L
01 03 1 10 HW
-
A summary display appears, showing zone 1s current programming or default values.
Zn ZT P RC In L
10 03 1 10 RF 1s
Enter the desired 2-digit zone number and press [].
Note: If you want to exit the Expert mode, enter 00 + [].
If an s appears after the loop number, it indicates that the transmitters serial number has been enrolled.
Use the [D] key to enter and duplicate wireless keys (see Entering Wireless Keys later)
Zn ZT P RC In L
10 03 1 10 RF
-
Enter all zone information except for Loop number, or press [C] to copy the zone information on this screen
from the last saved zone (including Loop).
ZT = Zone Type
P = Partition
RC = Report Code
In = Input Device Type
L = Loop number to which the sensor is connected.
NOTE: Pressing the [C] copies the zone information from the last saved zone, which includes the
input type. Verify this information is correct for this zone.
On this screen:
Use the [A] key to move to the right.
Use the [B] key to move to left and to back up to ZT field.
Press [] to accept the existing or newly entered zone information.