– 33 –
Relay Outputs Worksheets
Applicable only if relays (4204) or X-10 devices are used.
Programmed in the #93 Menu Mode in the Relay Programming Section. Fill in the worksheet below and follow the
procedure in the installation instructions as you enter the data during the displays and prompts that appear in sequence.
Notes: 1. For 4204 the Device Programming section must be programmed for the device address. Set the DIP
switches on the device for that address.
2. For X-10 devices, use the 1361X10 transformer in place of the transformer that comes in the box with the
control panel.
START
STOP
Restrict
1=4204
2=X-10
Dev Add 4204
or House Code
for X-10
Relay # for 4204
or
Unit Code for X-10
RELAY
DEV #
A
EV/ZL ZT / P ZL ZT / P
1.
2.
3.
4.
5.
6.
7.
8.
A = DEVICE ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off
EV = EVENT 0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble; 4 = Restore
ZL = ZONE LIST 1-4, 0 = Not Used
NOTES: "START" ZONE LIST: Upon alarm, fault, trouble or restore of ANY zone in this list, device action starts.
"STOP" ZONE LIST: Upon restore of ALL zones in this list, device action stops. It need not be same list as used for START.
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Types are:
00=zone not used 05=day/night burglary 10=interior (delay)
01=entry/exit 1 06=24-hour silent 20=arm stay
02=entry/exit 2 07=24-hour audible 21=arm away
03=perimeter 08=24-hour auxiliary 22=disarm
04=interior (follower) 09=supervised fire 23=no alarm response
NOTE: Any zone in "ZT" for Start, going into alarm, fault, or trouble will activate the relay.
Any zone in "ZT" for Stop, that restores will stop the relay action.
Choices for System Operation are:
00 = No Response (Not Used) 23 = No Alarm Response 43 = Communication failure
01 = Entry/Exit #1 31 = End of Exit Time 44 = RF Low Battery
02 = Entry/exit #2 32 = Start of Entry Time 45 = Polling Loop Failure
03 = Perimeter 33 = Any Burglary Alarm 51 = RF Receiver Failure
04 = Interior Follower 34 = Code + [#] + 71 Key Entry 52 = Kissoff
05 = Trouble Day/Alarm Night 35 = Code + [#] + 72 Key Entry 54 = Fire Zone Reset
06 = 24-Hr. Silent 36 = At Bell Timeout ** 55 = Disarm + 1 Minute
07 = 24-Hr. Audible 37 = 2 Times Bell Timeout ** 56 = XX Minutes (enter XX in field 1*74) *
08 = 24-Hr. Auxiliary 38 = Chime 57 = YY Seconds (enter YY in field 1*75) *
09 = Fire Alarm or Trouble 39 = Fire Alarm 58 = Duress
10 = Interior W/Delay 40 = Bypassing
20 = Arming-STAY 31 = End of Exit Time
21 = Arming-AWAY 41 = AC Power Fail
60 = Audio Alarm Verification (must be
selected for both START and STOP
operation)
22 = Disarming (Code + Off) 42 = System Battery Low
* Stop condition only ** Or at disarming, whichever occurs earlier
P = PARTITION No. 1-2, 0 = Any