Honeywell 2-Partitioned Security System Home Security System User Manual


 
21
Device Programming
This menu is used to program keypads, receivers, and relay modules, etc.
Device Address 00 is always set as an alpha keypad assigned to Partition 1 with no sounder suppression
options, and these settings cannot be changed.
From Data Field Programming mode, press [#]93 to display "ZONE PROG?" Press 0 repeatedly to display "DEVICE PROG?"
PROMPT
EXPLANATION
DEVICE PROG?
1=YES 0=NO 0
Press 1 to enter Device Programming.
DEVICE ADDRESS
01-15, 00=QUIT 01
The device address identifies the device to the control. Enter the 2-digit device address number to match
the devices physical address setting (01-15).
NOTE: If using the 4285/4286 Voice Module, it must be used at Device Address 04.
Select the type of addressable device as follows:
0 = device not used 3 = RF receiver (5881)
1 = alpha keypad (6139/6160) 4 = output relay module (4204)
2 = fixed keypad (6137/6150) 5 = voice (VIP) Module (4285/4286)
DEVICE TYPE
0
Press [] to accept entry.
Alpha Keypad
PROMPT
EXPLANATION
01 CONSOLE PART.
1
If you selected device type 1 (alpha keypad) or 2 (fixed keypad), this prompt appears. Enter the addressable
devices default partition number (1 to maximum number of partitions programmed for system in field 2*00).
This is the primary partition for the device.
Press [] to accept entry.
01 SOUND OPTION
00
Keypads can be individually programmed to suppress arm/disarm beeps, entry/exit beeps and chime mode
beeps. This helps prevent unwanted sounds from disturbing users in other areas of the premises.
Enter a number 00-03 for the keypad sounding suppression options desired for the keypad as follows:
00 = no suppression
01 = suppress arm/disarm & entry/exit beeps
02 = suppress chime mode beeps only
03 = suppress arm/disarm, entry/exit and chime mode beeps
Press [] to accept entry.
RF Expander
PROMPT
EXPLANATION
01 RF EXPANDER
HOUSE ID 00
If you selected device type 3 (RF receiver), this prompt appears. Enter the 2-digit House ID (00-31). This is
required if you are using a wireless keypad (5827/5827BD).
Press [] to accept entry.
VIP Module
PROMPT
EXPLANATION
01 MODULE PART.
1
If you selected device type 5 (VIP Module), this prompt appears. Enter the partition number 1-2 in which the
module is located.
Press [] to accept entry.
Press 00 + [] to exit Menu mode.
Press 99 to exit Program mode.