Heat & Glo LifeStyle SUPREME-N-I30AU Electric Heater User Manual


 
31Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12
Figure8.14OptionalSLPVentingConguration-VerticalTermination
SLP-TVHW
SLP 170 Ø
TWIN SKIN FLUE
LINK ADAPTER
CHIMNEY PLATE
(MADE TO ORDER)
FLEXIBLE FLUE
MAXIMUM
TOTAL FLUE
RUN 40 ft.
(12 m)
MINIMUM TOTAL
FLEXIBLE FLUE
RUN 35-7/16 ft
(900 mm)
MINIMUM 1/4 in. (6 mm)
NON-COMBUSTIBLE BASE (UNDER UNIT)
Mustadheretopipeclearances.
Colinear to Coaxial Adapter
NOTE:Any 3in.(76 mm)
section of flex pipemust
be enclosed to existing
fireplace flue in double
linedflue tocomplywith
AS2918-2001andthebuilding
codeofAustralia.
Seal connection points for duct-
ing.Sealantmusthaveaminimum
explosureratingof649°C(1200°F).