Heat & Glo LifeStyle SUPREME-N-I30AU Electric Heater User Manual


 
27Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12
MODEL FLUE TERMINATION APPROVAL
SUPREME-N-I30AU, SUPREME-P-I30AU LINK-DV30B VERTICAL TERMINATION CAP
TABLE 1
Figure8.8
MINIMUM TOTAL FLUE
RUN 10 ft. (3 m)
FLEXIBLE FLUE
SLP-TVHW
CHIMNEY PLATE
(MADE TO ORDER)
MINIMUM 1/4 in. (6 mm )
NON-COMBUSTIBLE BASE (UNDER UNIT)
MAXIMUM 39 ft. (12 m)
WARNING: THE EXHAUST PIPE
MUST ONLY BE CONNECTED TO THE
EXHAUST STARTING COLLAR OF THE
UNIT AND THE EXHAUST COLLAR OF
THE TERMINATION CAP.
THE INLET AIR PIPE MUST ONLY
BE CONNECTED TO THE INLET AIR
COLLAR OF THE UNIT AND ATTACHED
TO THE INLET AIR COLLAR OF THE
TERMINATION CAP. THE APPLIANCE
WILL NOT OPERATE PROPERLY IF
INCORRECTLY CONNECTED.
THIS IS A BALANCED FLUE HEATER
AND REQUIRES THE USE OF
BOTH FLUE LINERS AND MUST
TERMINATE TO THE CAP.
EXHAUST
COLLAR
INLET AIR
COLLAR
TERMINATION CAP