Heat & Glo LifeStyle SUPREME-N-I30AU Electric Heater User Manual


 
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/1228
F. VentKitsComponents
Direct Vent Flex Liner Accessory Kits (see Figure 8.9).
LINK-DV30B: Masonry 3 in. (76 mm) ex liner kit. Expands
to 30 ft. (9 m). Includes: two liners, termination cap,
ashing, and link adapter.
Flash-Damp: Zero clearance damper ashing kit for use
with the LINK-DV30B liner kit.
LINK-ZC-ADP: Zero clearance chimney adapter
DV-46DVA-GK: Adapter kit. It is permissible to use DV-
46DVA-GK to connect collinear ex vent to SL-D vent
pipe to extend the run.
FLEX3-30: One 3 in. (76 mm) exible liner expands to 30
ft . (9 m).
FLEX-CNCT: Connector kit - 3 in. (76 mm) liner to 3 in. (76
mm) liner, one connector per kit.
Figure8.9DirectVentFlexLinerAccessoryKits
FLASH-DAMP
FLEX3-30
LINK-DV30B
LINK-ZC-ADP
DV-46DVA-GK
FLEX-CNCT
G. Alternate Venting Congurations Using
AdaptationtoSLPVenting
This model is approved to use SLP Series ue pipe com-
ponents. A SLP-TVHW vertical Termination Cap must be
used for vertical terminations. A SLP-TRAP2 can be used
for horizontal terminations.
Approved ue system components are labeled for identi-
cation. NOOTHERFLUESYSTEMSORCOMPONENTS
MAYBEUSED. Detailed installation instructions are in-
cluded with each ue termination kit and should be used
in conjunction with this manual.
WARNING! Risk of Fire! This gas appliance and ue
assembly must be ued directly to the outside and must
never be attached to a chimney serving a separate solid
fuel burning appliance. Each gas appliance must use a
separate ue system-common ue systems are prohibited.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specied in
this manual. Overlapping material could ignite and will in-
terfere with proper operation of doors and louvers.
Horizontal sections 3 in. (76 mm) from the top of the
pipe.
Horizontal sections 2-1/2 in. (64 mm) at wall shield
restops.
Horizontal sections 1 in. (25 mm) from sides and bottom
of the pipe.
Vertical sections 1 in. (25 mm) on all sides of pipe.
Failure to keep insulation or other material away from vent
pipe may cause over heating and re.
For alternative installations, other than depicted, contact
your dealer for further information.