Heat & Glo LifeStyle BAY-40 Indoor Fireplace User Manual


 
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07
9
3
3
Framing and Clearances
A. Selecting Fireplace Location
Several options are available to you when choosing a loca-
tion for your replace. This replace may be used as a room
divider, installed along a wall, across a corner or used in an
exterior chase. See Figure 3.1.
72 in.
(1829 mm)
BAY-40 PIER-40
40-1/2 in.
(1029 mm)
HEARTH
EXTENSION
(shaded)
HEARTH
EXTENSION
(shaded)
1/2 in. min. distance from
fireplace to combustible
materials.
Note:
In addition to these
framing dimensions,
also reference the
following sections:
• Clearances (Section
3.B.)
• Mantel Projections
(Section 8.C)
• Fireplace Dimensions
(Section 12.A.)
Note:
6 in.
(152 mm)
12 in. (305 mm)
from opening of
fireplace
62 in.
(1575 mm)
16 in.
(406 mm)
56 in.
(1422 mm)
64 in.
(1626 mm)
64 in.
(1626 mm)
16 in.
(406 mm)
26 in.
(660 mm)
to front of
fireplace
opening
Figure 3.1 Fireplace Locations
Fire Risk
Provide adequate clearances.
Around air openings
• To combustibles
For service access.
Locate replace away from traf c areas.
WARNING
Note:
Illustrations and photos re ect typical installations
and are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation/appearance may vary due to
individual design preference.
Hearth & Home Technologies reserves the right to
alter its products.
Locating the replace in a basement, near frequently opened
doors, central heat outlets or returns, or other locations of
considerable air movement can affect the performance and
cause intermittent smoke spillage from the front of the re-
place. Consideration should be given to these factors before
deciding on a location. See Sections 2 and 10.